Clinically relevant differences in the selection of toric intraocular lens power in normal eyes: preoperative measurement vs intraoperative aberrometry
- PMID: 31239634
- PMCID: PMC6551590
- DOI: 10.2147/OPTH.S205352
Clinically relevant differences in the selection of toric intraocular lens power in normal eyes: preoperative measurement vs intraoperative aberrometry
Abstract
Purpose: To assess the value of intraoperative aberrometry (IA) in determining toric intraocular lens (IOL) power in eyes with no previous ocular surgery. Patients and methods: This was a retrospective data review at one US clinical site of eyes that underwent uncomplicated cataract surgery with toric IOL implantation where standard preoperative and IA measurements were available. Calculated IOL sphere and cylinder powers and orientation were compared based on the measurement method and the postoperative refraction, using both actual and simulated (back-calculated) results. Comparisons were between the surgeon's preoperative calculations, IA measurements, the actual IOL implanted and results from the Barrett toric calculator. Results: There was no significant difference (p>0.7) in the number of eyes expected to have, or having, a spherical equivalent refraction within 0.50D of the target between Actual (92%), IA (93%) or Preoperative calculation results (86%). The percentage of eyes with expected residual refractive astigmatism ≤0.50D was significantly higher for the IA vs Preoperative calculations (75% vs 53%, p<0.01). There was no significant difference in expected results between the Actual, IA and Barrett toric calculations (p>0.65). Conclusion: Modern IOL calculations for sphere produced results comparable to those achieved with IA. The value of IA in determining IOL cylinder power and orientation was more evident when comparing expected results between IA and a preoperative method based on measured total corneal astigmatism than when comparing to expected results from the Barrett toric calculator.
Keywords: IOL power calculation; ORA; astigmatism; prediction error; refraction; toric IOL.
Conflict of interest statement
Dr James A Davison reports grants from Alcon, during the conduct of the study. Dr Sarah Makari reports grants from Alcon, during the conduct of the study and outside the submitted work. Dr Richard Potvin reports grants from Alcon, during the conduct of the study. The authors report no other conflicts of interest in this work.
Similar articles
-
Evaluating the relative value of intraoperative aberrometry versus current formulas for toric IOL sphere, cylinder, and orientation planning.J Cataract Refract Surg. 2019 Oct;45(10):1430-1435. doi: 10.1016/j.jcrs.2019.05.023. J Cataract Refract Surg. 2019. PMID: 31564316
-
Clinical outcomes after aphakic versus aphakic/pseudophakic intraoperative aberrometry in cataract surgery with toric IOL implantation.Int Ophthalmol. 2020 Dec;40(12):3251-3257. doi: 10.1007/s10792-020-01509-y. Epub 2020 Aug 8. Int Ophthalmol. 2020. PMID: 32770491 Clinical Trial.
-
Preoperative measurement vs intraoperative aberrometry for the selection of intraocular lens sphere power in normal eyes.Clin Ophthalmol. 2017 May 17;11:923-929. doi: 10.2147/OPTH.S135659. eCollection 2017. Clin Ophthalmol. 2017. PMID: 28553072 Free PMC article.
-
Intraoperative aberrometry: an update on applications and outcomes.Curr Opin Ophthalmol. 2023 Jan 1;34(1):48-57. doi: 10.1097/ICU.0000000000000915. Epub 2022 Oct 20. Curr Opin Ophthalmol. 2023. PMID: 36484210 Review.
-
A Review of Smartphone Apps Used for Toric Intraocular Lens Calculation and Alignment.Vision (Basel). 2022 Feb 18;6(1):13. doi: 10.3390/vision6010013. Vision (Basel). 2022. PMID: 35225972 Free PMC article. Review.
Cited by
-
Astigmatism Management with Astigmatism-Correcting Intraocular Lens Using Two Toric Calculators - A Comparative Case Series.Clin Ophthalmol. 2021 Aug 5;15:3259-3266. doi: 10.2147/OPTH.S325234. eCollection 2021. Clin Ophthalmol. 2021. PMID: 34385813 Free PMC article.
-
Astigmatism Management in Modern Cataract Surgery.Vision (Basel). 2024 Feb 27;8(1):9. doi: 10.3390/vision8010009. Vision (Basel). 2024. PMID: 38535758 Free PMC article. Review.
-
Accuracy of Intraoperative Aberrometry-Based Prediction of Postoperative Refraction and Astigmatism After Novel Toric Intraocular Lens Implantation.Clin Ophthalmol. 2025 Aug 11;19:2681-2689. doi: 10.2147/OPTH.S534932. eCollection 2025. Clin Ophthalmol. 2025. PMID: 40823161 Free PMC article.
-
Clinical evaluation of toric intraocular lens implantation based on iTrace wavefront keratometric astigmatism.BMC Ophthalmol. 2020 Nov 16;20(1):450. doi: 10.1186/s12886-020-01726-0. BMC Ophthalmol. 2020. PMID: 33198718 Free PMC article.
References
LinkOut - more resources
Full Text Sources