The value of ABR- and ASSR-based hearing estimation in young children with congenital monaural malformation (atresia)
- PMID: 31240977
- DOI: 10.1080/00016489.2019.1630756
The value of ABR- and ASSR-based hearing estimation in young children with congenital monaural malformation (atresia)
Abstract
Background: The electrophysiology of auditory nerve mature is particularly important for unilateral hearing loss. Objectives: To assess the hearing status in young children with congenital monaural malformation and evaluate their potential for practical use in the functional maturation parameters of the auditory pathway. Materials and methods: ABR (auditory brainstem responses) and ASSR (auditory steady-state responses) threshold measurements were performed in 21 young children with congenital monaural atresia. Results: The average electrophysiologic thresholds for the ABR were 65 dB nHL ± 1.20 in malformed ears and 25 dB nHL ± 0.48 in normal ones. All 21 atretic ears presented with typical conductive hearing loss. There was no statistic positive correlation in hearing-impaired ears between the methods of ABR and ASSR responses (r = 0.12, 0.20 and 0.17). The IPL (interpeak latency) of I-III, III-V and I-V of atretic ears in ABR test was decreased relative to normal ears. Furthermore, a shortening of the IPLs I-III, III-V, I-V can be observed with increasing age of the children in malformed ears. Conclusions and significance: The ABR- and ASSR-based hearing evaluation in young children with congenital monaural malformation should be viewed as complementary technologies. Besides, there was no delay of functional maturation at brainstem level although unilateral hearing was deprived during their early years of life.
Keywords: Auditory brainstem response; auditory pathway; auditory steady-state response; monaural malformation.
Similar articles
-
Maturation of auditory brainstem responses in young children with congenital monaural atresia.Int J Pediatr Otorhinolaryngol. 2017 Apr;95:39-44. doi: 10.1016/j.ijporl.2017.01.029. Epub 2017 Jan 29. Int J Pediatr Otorhinolaryngol. 2017. PMID: 28576530
-
Evaluation of Speed and Accuracy of Next-Generation Auditory Steady State Response and Auditory Brainstem Response Audiometry in Children With Normal Hearing and Hearing Loss.Ear Hear. 2018 Nov/Dec;39(6):1207-1223. doi: 10.1097/AUD.0000000000000580. Ear Hear. 2018. PMID: 29624540 Free PMC article.
-
A Comparison of Thresholds of Auditory Steady-State Response and Auditory Brainstem Response in Healthy Term Babies.J Int Adv Otol. 2016 Dec;12(3):277-281. doi: 10.5152/iao.2016.2397. Epub 2016 Nov 28. J Int Adv Otol. 2016. PMID: 27897125
-
[On possible causes of discrepancy between the results of auditory brainstem responses (ABR) and auditory steady-state responses (ASSR) recordings].Vestn Otorinolaringol. 2025;90(1):64-68. doi: 10.17116/otorino20259001164. Vestn Otorinolaringol. 2025. PMID: 40099337 Review. Russian.
-
Unraveling the Mystery of Auditory Brainstem Response Corrections: The Need for Universal Standards.J Am Acad Audiol. 2017 Nov/Dec;28(10):950-960. doi: 10.3766/jaaa.16112. J Am Acad Audiol. 2017. PMID: 29130443 Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Miscellaneous