. 2019 Sep;46(9):949-957.
doi: 10.1111/jcpe.13160. Epub 2019 Jul 19.

The accuracy of single-tooth implants placed using fully digital-guided surgery and freehand implant surgery

Affiliations
Randomized Controlled Trial

The accuracy of single-tooth implants placed using fully digital-guided surgery and freehand implant surgery

Palita Smitkarn et al. J Clin Periodontol. 2019 Sep.

Abstract

Aim: This randomized controlled clinical trial (RCT) aimed to compare the accuracy of implant positions between static computer-assisted implant surgery (CAIS) and freehand implant surgery in a single edentulous space.

Materials and methods: Sites with single edentulous spaces and neighbouring natural teeth were randomized into static CAIS or freehand implant surgery groups. In both groups, digital implant planning was performed using data from cone beam computed tomography (CBCT) and surface scans. In the static CAIS group, a surgical guide was produced and used for fully guided implant surgery, while in the freehand group, the implants were placed in a freehand manner. Postoperative CBCT was used for nine measurements representing the deviations in angles, implant shoulders and apexes between planned and actual implant positions.

Results: Fifty-two patients received 60 single implants. The median (IQR) deviations in angles, shoulders and apexes were 2.8 (2.6)°, 0.9 (0.8) mm and 1.2 (0.9) mm, respectively, in the static CAIS group, and 7.0 (7.0)°, 1.3 (0.7) mm and 2.2 (1.2) mm, respectively, in the freehand group. Statistically significant differences were found in 6 out of nine measured parameters using Mann-Whitney U test (p < 0.05).

Conclusion: Static CAIS provided more accuracy in implant positions than freehand placement in a single edentulous space.

Keywords: accuracy of implant position; dental implant; freehand implant surgery; static computer-assisted implant surgery.

PubMed Disclaimer

References

REFERENCES

    1. Assche, N., Vercruyssen, M., Coucke, W., Teughels, W., Jacobs, R., & Quirynen, M. (2012). Accuracy of computer-aided implant placement. Clinical Oral Implants Research, 23(6), 112-123. https://doi.org/10.1111/j.1600-0501.2012.02552.x
    1. Behneke, A., Burwinkel, M., & Behneke, N. (2012). Factors influencing transfer accuracy of cone beam CT-derived template-based implant placement. Clinical Oral Implants Research, 23(4), 416-423. https://doi.org/10.1111/j.1600-0501.2011.02337.x
    1. Choi, W., Nguyen, B.-C., Doan, A., Girod, S., Gaudilliere, B., & Gaudilliere, D. (2017). Freehand versus guided surgery: Factors influencing accuracy of dental implant placement. Implant Dentistry, 26(4), 500-509. https://doi.org/10.1097/ID.0000000000000620
    1. Cooper, L. F. (2015). Prosthodontic complications related to non-optimal dental implant placement. In S. J. Froum (Ed.), Dental implant complications: Etiology, prevention, and treatment (2nd ed., pp. 539-558). New York, NY: Wiley-Blackwell.
    1. de Almeida, E. O., Pellizzer, E. P., Goiatto, M. C., Margonar, R., Rocha, E. P., Freitas, A. C. Jr, & Anchieta, R. B. (2010). Computer-guided surgery in implantology: Review of basic concepts. Journal of Craniofacial Surgery, 21(6), 1917-1921. https://doi.org/10.1097/SCS.0b013e3181f4b1a0

Publication types

Substances

LinkOut - more resources