. 2019 Oct;82(10):1642-1648.
doi: 10.1002/jemt.23330. Epub 2019 Jun 29.

Cyclic fatigue resistance of rotary NiTi instruments produced with four different manufacturing methods

Affiliations

Cyclic fatigue resistance of rotary NiTi instruments produced with four different manufacturing methods

Neslihan B Keskin et al. Microsc Res Tech. 2019 Oct.

Abstract

The aim of this study was to compare the cyclic fatigue resistance of rotary NiTi files, produced with four different manufacturing methods on specially designed dynamic models that simulated clinical conditions. In this study, 120 files, consisting of 30 files for Typhoon, ProTaper Next, RaCe, and Twisted Files nickel titanium rotary systems were used. The 30 files of each group were divided into three subgroups to be used in artificial canals with a 60° angle of curvature and radii of curvature of 2, 5, and 8 mm (n = 10). All files were rotated in the artificial canals until fracture occurred and the number of cycles to fracture was calculated. The data were analyzed using one- and two-way analyses of variance and Tamhane multiple comparison tests. In all three groups, Typhoon instruments had the highest number of cycles to failure than the RaCe, ProTaper Next, and Twisted Files instruments, and the difference statistically significant (p < .05). There were no significant differences between the RaCe, ProTaper Next, and Twisted Files groups (p > .05). The CM wire Typhoon system was significantly more resistant to cyclic fatigue compared to the other file systems in all three artificial canals. When the fracture resistance of an instrument in three different artificial canals was compared, the mean NCFs decreased as the radius of the curvature of the canal decreased from 8 to 2 mm. Manufacturing method is one of the most important factors on cyclic fatigue resistance, also the radius of curvature effects the cyclic fatigue.

Keywords: cyclic fatigue resistance; endodontics; fracture; nickel-titanium.

PubMed Disclaimer

References

REFERENCES

    1. Al-Hadlaq, S. M., Aljarbou, F. A., & AlThumairy, R. I. (2010). Evaluation of cyclic flexural fatigue of M-wire nickel-titanium rotary instruments. Journal of Endodontia, 36(2), 305-307. https://doi.org/10.1016/j.joen.2009.10.032
    1. Anderson, M. E., Price, J. W., & Parashos, P. (2007). Fracture resistance of electropolished rotary nickel-titanium endodontic instruments. Journal of Endodontia, 33(10), 1212-1216. https://doi.org/10.1016/j.joen.2007.07.007
    1. Bhagabati, N., Yadav, S., & Talwar, S. (2012). An in vitro cyclic fatigue analysis of different endodontic nickel-titanium rotary instruments. Journal of Endodontia, 38(4), 515-518. https://doi.org/10.1016/j.joen.2011.12.034
    1. Boessler, C., Paque, F., & Peters, O. A. (2009). The effect of electropolishing on torque and force during simulated root canal preparation with ProTaper shaping files. Journal of Endodontia, 35(1), 102-106. https://doi.org/10.1016/j.joen.2008.09.008
    1. Bui, T. B., Mitchell, J. C., & Baumgartner, J. C. (2008). Effect of electropolishing ProFile nickel-titanium rotary instruments on cyclic fatigue resistance, torsional resistance, and cutting efficiency. Journal of Endodontia, 34(2), 190-193. https://doi.org/10.1016/j.joen.2007.10.007

LinkOut - more resources