. 2019 Jun 12;8(2):e000378.
doi: 10.1136/bmjoq-2018-000378. eCollection 2019.

Improving the accuracy of digital templating: achieving success through stakeholder management

Affiliations

Improving the accuracy of digital templating: achieving success through stakeholder management

Hammad Parwaiz et al. BMJ Open Qual. .

Abstract

The use of a marker ball in digital templating for hip arthroplasty is a well-established method of preoperative planning and is used to overcome the inherent magnification in plain film radiographs. Our hospital policy is to place a marker ball in all anteroposterior pelvic films taken in the emergency department (ED) which have been requested for suspected neck of femur fractures. We carried out a baseline measurement followed by three Plan-Do-Study-Act cycles for all pelvic films taken in ED during July 2016, November 2016, February 2017 and November 2017. Interventions between the baseline measurement and cycle 1 were to educate the lead radiographer and publish the results in the radiology newsletter, and between cycles 1 and 2 was to run a teaching session for radiographers, display posters in the X-ray department and place an electronic prompt on the X-ray machine to alert them of the need to place a marker ball in the X-ray field. Cycle 3 looked to see if improvements were sustained. 16/81 (20%) radiographs complied with the policy in our baseline measurement; 25/51 (46%, p=0.002) in cycle 1; 40/54 (74%, p=0.0056) in cycle 2; and 48/63 (76%) in cycle 3. Our quality improvement project led to large improvements in clinical practice through straightforward, small, but appropriately targeted interventions. Stakeholder management is key to successfully implementing change. The next step is to switch from the VoyantMark to the KingMark marker ball, as it has greater accuracy of templating and is also easier to place within the field of an X-ray.

Keywords: PDSA; hip fracture; marker ball; stakeholder management; templating.

PubMed Disclaimer

Conflict of interest statement

Competing interests: None declared.

Figures

Figure 1
Figure 1
An example of an anteroposterior (AP) pelvic radiograph taken for a suspected neck of femur fracture in the emergency department. At the bottom of the image is an example of a well-placed marker ball.
Figure 2
Figure 2
Compliance of pelvic radiographs with trust policy during each Plan-Do-Study-Act (PDSA) cycle.

References

    1. Eggli S, Pisan M, Muller ME. The value of preoperative planning for total hip arthroplasty. Journal of Bone and Joint Surgery 1998;80B:382–90. - PubMed
    1. Kwok IHY, Pallett SJC, Massa E, et al. . Pre-operative digital templating in cemented hip hemiarthroplasty for neck of femur fractures. Injury 2016;47:733–6. 10.1016/j.injury.2015.12.027 - DOI - PubMed
    1. Lakstein D, Bachar I, Debi R, et al. . Radiographic templating of total hip arthroplasty for femoral neck fractures. Int Orthop 2017;41:831–6. 10.1007/s00264-016-3235-y - DOI - PubMed
    1. Shin JK, Son SM, Kim TW, et al. . Accuracy and reliability of preoperative On-screen templating using digital radiographs for total hip arthroplasty. Hip Pelvis 2016;28:201–7. 10.5371/hp.2016.28.4.201 - DOI - PMC - PubMed
    1. Steinberg EL, Shasha N, Menahem A, et al. . Preoperative planning of total hip replacement using the TraumaCad™ system. Arch Orthop Trauma Surg 2010;130:1429–32. 10.1007/s00402-010-1046-y - DOI - PubMed

MeSH terms

LinkOut - more resources