Randomized Controlled Trial
. 2019 Aug;477(8):1851-1857.
doi: 10.1097/CORR.0000000000000804.

Perineal Pressure During Hip Arthroscopy Is Reduced by Use of Trendelenburg: A Prospective Study With Randomized Order of Positioning

Affiliations
Randomized Controlled Trial

Perineal Pressure During Hip Arthroscopy Is Reduced by Use of Trendelenburg: A Prospective Study With Randomized Order of Positioning

Ajay C Lall et al. Clin Orthop Relat Res. 2019 Aug.

Abstract

Background: The use of traction during hip arthroscopy is commonly used to provide safe joint access and to improve visualization. However, traction during hip arthroscopy has been associated with complications ranging from transient neuropraxias to devastating soft-tissue necrosis. Trendelenburg positioning may be helpful, but the degree to which this is true is not well understood.

Questions/purposes: To determine whether there would be a reduction in perineal pressure at 5°, 10°, and 15° of Trendelenburg compared with baseline (0° of Trendelenburg) while in the modified supine position during hip arthroscopy.

Methods: A consecutive cohort of 50 patients treated with hip arthroscopy by a single, high-volume orthopaedic surgeon was analyzed. There were 30 females and 20 males in this study, with a mean age of 36 ± 16 years (range, 14 to 66 years); mean BMI was 26 kg/m. In the operating room, patients were placed in the modified supine position on a traction extension table with a well-padded perineal post. A standard blood pressure cuff was secured to the post to measure pressure exerted on the perineum as traction was applied to distract the hip. For each patient, pressure against the perineum was measured at four different positions using a digital level: 0°, 5°, 10°, and 15° of Trendelenburg. These positions were tested in a random order for each patient. Mean pressure was compared within patients under the four-period crossover design using a repeated-measure (mixed) ANOVA model. Examination of the residual error quantile plot showed that the pressure data followed a normal distribution, making the use of a parametric model appropriate. Tests were made for period and order effects.

Results: Compared with baseline (0° or no Trendelenburg) there was a reduction in pressure of 4.4 (15.5%) at 5° of Trendelenburg (p = 0.203), 8 (28%) at 10° of Trendelenburg (p = 0.022) and 13.1 (46%) at 15° (p = 0.006). These results were maintained regardless of the sequence of positions used in each patient (0°, 5°, 10°, 15°).

Conclusions: Trendelenburg positioning of 10° and 15° during hip arthroscopy resulted in decreased perineal pressure compared with the neutral (0°) position. This technique is intended to harness gravity to exert the majority of countertraction while retaining the perineal post as a backup patient stabilizer. Routine introduction of Trendelenburg during hip arthroscopy reduces perineal pressure against the post, which may decrease complications related to traction and perineal pressure. Future studies should assess whether the observed differences in perineal pressure will reduce the frequency of post-related complications after hip arthroscopy.

Level of evidence: Level II, therapeutic study.

PubMed Disclaimer

Conflict of interest statement

All ICMJE Conflict of Interest Forms for authors and Clinical Orthopaedics and Related Research® editors and board members are on file with the publication and can be viewed on request.

Figures

Fig. 1
Fig. 1
Examination of the residual error quantile plot showed that the pressure data followed a normal distribution, making the use of a parametric model appropriate.
Fig. 2
Fig. 2
A decrease in pressure (Hg) with bed position at increasing angle of Trendelenburg is shown.

Comment in

References

    1. Byrd JT. Physical Examination. In: Byrd JT, ed. Operative Hip Arthroscopy. New York: Springer; 2005:36–50.
    1. Byrd JW. Hip arthroscopy utilizing the supine position. Arthroscopy. 1994;10:275–280. - PubMed
    1. Byrd JW, Chern KY. Traction versus distension for distraction of the joint during hip arthroscopy. Arthroscopy. 1997;13:346–349. - PubMed
    1. Byrd JW, Pappas JN, Pedley MJ. Hip arthroscopy: an anatomic study of portal placement and relationship to the extra-articular structures. Arthroscopy. 1995;11:418–423. - PubMed
    1. Callanan I, Choudhry V, Smith H. Perineal sloughing as a result of pressure necrosis from the traction post during prolonged bilateral femoral nailing. Injury. 1994;25:472. - PubMed

Publication types

MeSH terms