Effects of nasal cold receptors on pattern of breathing
- PMID: 3128527
- DOI: 10.1152/jappl.1988.64.1.371
Effects of nasal cold receptors on pattern of breathing
Abstract
To investigate the effect on the pattern of breathing of cooling receptors in the nose, eight normal male volunteers underwent a steady-state CO2 stimulation by nasal inhalation. The inhaled gas temperature was randomly switched between "warm" (32 degrees C) and "cold" (2 degrees C) at each of three levels of inspired CO2 fraction (FICO2). Breathing cold air through the nose reduced the mean slope of the ventilatory response to CO2 by 27% (P less than 0.05) and the mean intercept at PCO2 of 45 Torr by 6.6 l/min (P less than 0.01). This was due mainly to a reduction in tidal volume (VT). Analysis of the breathing pattern recorded at a high level of minute ventilation (VE) (end-tidal partial pressure of CO2 approximately 52 Torr) showed a reduction of VE that was due almost entirely to a reduction in VT (P less than 0.05) associated with a reduction in inspiratory time (TI) as a fraction of total respiratory cycle time (P less than 0.05) but little change in VT/TI. In a separate experiment conducted with five subjects, there was no significant difference in inspired nasal resistance between warm and cold runs during CO2-stimulated breathing. The results confirm the previous observation that cold air breathed through the nose inhibits ventilation in normal subjects and show that this is not related to an increase in flow resistance. The reduction in ventilation is due to reduction in VT associated with shortening of the duty cycle.
Similar articles
-
An assessment of nasal functions in control of breathing.J Appl Physiol (1985). 1988 Oct;65(4):1520-4. doi: 10.1152/jappl.1988.65.4.1520. J Appl Physiol (1985). 1988. PMID: 3141357
-
Reducing ventilatory response to carbon dioxide by breathing cold air.Am Rev Respir Dis. 1984 May;129(5):687-90. doi: 10.1164/arrd.1984.129.5.687. Am Rev Respir Dis. 1984. PMID: 6426352
-
Effect of inspired air temperature on genioglossus activity during nose breathing in awake humans.J Appl Physiol (1985). 1990 Sep;69(3):1098-103. doi: 10.1152/jappl.1990.69.3.1098. J Appl Physiol (1985). 1990. PMID: 2123177
-
No evidence for hypothalamic cooling during nasal cold air breathing in man.Clin Invest Med. 1988 Apr;11(2):134-8. Clin Invest Med. 1988. PMID: 3135135
-
Effect of posture on the ventilatory response to CO2.J Appl Physiol Respir Environ Exerc Physiol. 1982 Sep;53(3):761-5. doi: 10.1152/jappl.1982.53.3.761. J Appl Physiol Respir Environ Exerc Physiol. 1982. PMID: 6813303
Cited by
-
Odor thresholds and breathing changes of human volunteers as consequences of sulphur dioxide exposure considering individual factors.Saf Health Work. 2011 Dec;2(4):355-64. doi: 10.5491/SHAW.2011.2.4.355. Epub 2011 Dec 5. Saf Health Work. 2011. PMID: 22953220 Free PMC article.
-
Menthol: effects on nasal sensation of airflow and the drive to breathe.Curr Allergy Asthma Rep. 2003 May;3(3):210-4. doi: 10.1007/s11882-003-0041-6. Curr Allergy Asthma Rep. 2003. PMID: 12662469 Review.
-
Chronic cough in subjects with upper airway diseases - analysis of mechanisms and clinical applications.Asia Pac Allergy. 2013 Apr;3(2):127-35. doi: 10.5415/apallergy.2013.3.2.127. Epub 2013 Apr 26. Asia Pac Allergy. 2013. PMID: 23667837 Free PMC article.
-
Oral Cooling and Carbonation Increase the Perception of Drinking and Thirst Quenching in Thirsty Adults.PLoS One. 2016 Sep 29;11(9):e0162261. doi: 10.1371/journal.pone.0162261. eCollection 2016. PLoS One. 2016. PMID: 27685093 Free PMC article.
-
L-Menthol Olfactory Stimulation Reduced Dyspnea Sensation during the 6 min Walk Test in Patients with Chronic Breathlessness Syndrome: A Pilot Study.J Clin Med. 2023 Aug 27;12(17):5587. doi: 10.3390/jcm12175587. J Clin Med. 2023. PMID: 37685654 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources