Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2019 Jul 1;35(7):418-425.
doi: 10.3928/1081597X-20190528-02.

Prospective Comparison of Clinical Performance and Subjective Outcomes Between Two Diffractive Trifocal Intraocular Lenses in Bilateral Cataract Surgery

Randomized Controlled Trial

Prospective Comparison of Clinical Performance and Subjective Outcomes Between Two Diffractive Trifocal Intraocular Lenses in Bilateral Cataract Surgery

Tiago B Ferreira et al. J Refract Surg. .

Abstract

Purpose: To compare clinical outcomes and subjective experience after bilateral implantation of two non-toric diffractive trifocal intraocular lenses (IOLs).

Methods: In a prospective, comparative case series, patients were randomly allocated to receive bilateral implantation of either the preloaded RayOne Trifocal (Rayner, Worthing, UK) or the FineVision POD F (PhysIOL, Liège, Belgium). At the 3-month follow-up, the main outcomes were monocular and binocular uncorrected and corrected distance (UDVA, CDVA), intermediate at 80 cm (UIVA, DCIVA), and near at 40 cm (UNVA, DCNVA) visual acuities, refractive outcomes, and defocus curves. Patients' satisfaction in terms of visual disturbance was also evaluated.

Results: Each group comprised 30 eyes (15 patients). The mean monocular UDVA was 0.03 ± 0.11 (RayOne Trifocal) and 0.04 ± 0.08 (FineVision POD F) logMAR (P = .605); DCIVA was 0.05 ± 0.13 and 0.05 ± 0.10 logMAR, respectively (P > .999); and DCNVA was 0.02 ± 0.12 and 0.03 ± 0.11 logMAR (P = .742). A better manifest spherical equivalent was found in the RayOne Trifocal than in the FineVision POD F group (P = .035) and depth perception issues were less severe with the RayOne Trifocal IOL (P = .042). There was no significant difference in other photic phenomena between groups.

Conclusions: Both IOLs provided good visual outcomes at all distances with no differences between the groups. Refractive accuracy was better for the RayOne Trifocal IOL. The results indicated that the new trifocal IOL may represent a safe and effective option for presbyopic patients. [J Refract Surg. 2019;35(7):418-425.].

PubMed Disclaimer

Publication types

LinkOut - more resources