Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2019 Oct:62:181-190.
doi: 10.1016/j.mri.2019.07.005. Epub 2019 Jul 11.

Amide proton transfer imaging of glioblastoma, neuroblastoma, and breast cancer cells on a 11.7 T magnetic resonance imaging system

Affiliations

Amide proton transfer imaging of glioblastoma, neuroblastoma, and breast cancer cells on a 11.7 T magnetic resonance imaging system

Minori Tanoue et al. Magn Reson Imaging. 2019 Oct.

Abstract

Purpose: The purpose of this study was (i) to determine the optimal magnetization transfer (MT) pulse parameter for amide proton transfer (APT) chemical exchange saturation transfer (CEST) imaging on an ultra-high-field magnetic resonance imaging (MRI) system and (ii) to use APT CEST imaging to noninvasively assess brain orthotopic and ectopic tumor cells transplanted into the mouse brain.

Methods: To evaluate APT without the influence of other metabolites, we prepared egg white phantoms. Next, we used 7-11-week-old nude female mice and the following cell lines to establish tumors after injection into the left striatum of mice: C6 (rat glioma, n = 8) as primary tumors and Neuro-2A (mouse neuroblastoma, n = 11) and MDA-MB231 (human breast cancer, n = 8) as metastatic tumors. All MRI experiments were performed on an 11.7 T vertical-bore scanner. CEST imaging was performed at 1 week after injection of Neuro-2A cells and at 2 weeks after injection of C6 and MDA-MB231 cells. The MT pulse amplitude was set at 2.2 μT or 4.4 μT. We calculated and compared the magnetization transfer ratio (MTR) and difference of MTR asymmetry between normal tissue and tumor (ΔMTR asymmetry) on APT CEST images between mouse models of brain tumors. Then, we performed hematoxylin and eosin (HE) staining and Ki-67 immunohistochemical staining to compare the APT CEST effect on tumor tissues and the pathological findings.

Results: Phantom study of the amide proton phantom containing chicken egg white, z-spectra obtained at a pulse length of 500 ms showed smaller peaks, whereas those obtained at a pulse length of 2000 ms showed slightly higher peaks. The APT CEST effect on tumor tissues was clearer at a pulse amplitude of 2.2 μT than at 4.4 μT. For all mouse models of brain tumors, ΔMTR asymmetry was higher at 2.2 μT than at 4.4 μT. ΔMTR asymmetry was significantly higher for the Neuro-2A model than for the MDA-MB231 model. HE staining revealed light bleeding in Neuro-2A tumors. Immunohistochemical staining revealed that the density of Ki-67-positive cells was higher in Neuro-2A tumors than in C6 or MDA-MB231 tumors.

Conclusion: The MTR was higher at 4.4 μT than at 2.2 μT for each concentration of egg white at a pulse length of 500 ms or 2000 ms. High-resolution APT CEST imaging on an ultra-high-field MRI system was able to provide tumor information such as proliferative potential and intratumoral bleeding, noninvasively.

Keywords: Amide proton imaging; Chemical exchange saturation transfer; Glioma; Magnetic resonance imaging.

PubMed Disclaimer

Similar articles

Cited by

Publication types

MeSH terms

LinkOut - more resources