Blood flow velocity in pulmonary microvessels of bullfrog
- PMID: 313064
- DOI: 10.1016/0034-5687(79)90091-4
Blood flow velocity in pulmonary microvessels of bullfrog
Abstract
Flow velocity in the pulmonary microvessels of the exposed lung of bullfrogs was measured by means of a laser Doppler microscope of an oblique backward mode, together with a signal-analyzing system having a time sharing circuit triggered by the R-wave of the ECG. By these means, measurements of the changes of flow velocity contour in the cardiac cycle were made. Flow velocity was clearly pulsatile in response to cardiac cycles in all microvessels including capillaries. Flow velocities in the arteriole and venule consistently decreased for a short period after the R-wave (84 +/- 33 msec (mean +/- SD) in the arteriole and 130 +/- 31 msec in the venule, respectively) and rapidly increased up to a maximicronm value. The mean flow velocities in arterioles (diameter 50 +/- 17 micron) and venules (39 +/- 9 micronm) were 2.29 +/- 0.32 and 2.30 +/- 0.27 mm/sec. The amplitudes of pulsatile flow in these vessels were 0.83 +/- 0.31 and 0.63 +/- 0.16 mm/sec, respectively. In the capillary the times from the R-wave to the minimicronm and maximum values were variable. In some cases the velocity gradually increased without first decreasing and the increase sharply accelerated a certain time after the R-wave. The mean velocity in the pulmonary capillary and the amplitude of the pulsatile flow ere 1.78 +/- 0.31 and 0.37 +/- 0.12 mm/sec, resepctively. The ratios of the pulsatile amplitude to the mean velocity in the pulmonary capillary, venule and arteriole averaged 0.21, and 0.36, respectively.
Similar articles
-
[Measurements of blood flow velocity in pulmonary microvessels with laser-Doppler microscope and investigation of several factors affecting the blood flow velocity (author's transl)].Hokkaido Igaku Zasshi. 1981 Sep;56(5):507-18. Hokkaido Igaku Zasshi. 1981. PMID: 6976299 Japanese.
-
Laser Doppler microscope in an oblique-backward mode and pulsatile blood flow velocity in pulmonary arteriole.Experientia. 1979 Jan 15;35(1):65-7. doi: 10.1007/BF01917880. Experientia. 1979. PMID: 311296
-
Hypoxic reduction in blood flow velocity in pulmonary arterioles and capillaries.Adv Exp Med Biol. 1984;169:651-60. doi: 10.1007/978-1-4684-1188-1_59. Adv Exp Med Biol. 1984. PMID: 6610285
-
Pulmonary microcirculatory response to localized hypercapnia.J Appl Physiol Respir Environ Exerc Physiol. 1982 Dec;53(6):1556-64. doi: 10.1152/jappl.1982.53.6.1556. J Appl Physiol Respir Environ Exerc Physiol. 1982. PMID: 6984042
-
Effect of transpulmonary pressure on blood-flow velocity in pulmonary microvessels.Respir Physiol. 1981 Jan;43(1):31-41. doi: 10.1016/0034-5687(81)90086-4. Respir Physiol. 1981. PMID: 7244425
Cited by
-
Inference of alveolar capillary network connectivity from blood flow dynamics.Am J Physiol Lung Cell Mol Physiol. 2024 Dec 1;327(6):L852-L866. doi: 10.1152/ajplung.00025.2024. Epub 2024 Sep 25. Am J Physiol Lung Cell Mol Physiol. 2024. PMID: 39320092 Free PMC article.
MeSH terms
LinkOut - more resources
Other Literature Sources