Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2019 Oct 15:248:109258.
doi: 10.1016/j.jenvman.2019.07.029. Epub 2019 Jul 17.

Simultaneous removal of polycyclic aromatic hydrocarbons and heavy metals from natural soil by combined non-ionic surfactants and EDTA as extracting reagents: Laboratory column tests

Affiliations

Simultaneous removal of polycyclic aromatic hydrocarbons and heavy metals from natural soil by combined non-ionic surfactants and EDTA as extracting reagents: Laboratory column tests

Mohsen Saeedi et al. J Environ Manage. .

Abstract

Simultaneous removal of three polycyclic aromatic hydrocarbons (acenaphthene, fluorene and fluoranthene) co-existing with three heavy metals (Ni, Pb and Zn) in artificially contaminated soil from the vicinity of an oil refinery was examined by column flushing of solutions containing Triton X-100 + Ethylenediaminetetraacetic acid (EDTA) and Tween 80 + EDTA at three levels of surfactant concentrations. While the effectiveness of both combined solutions in removal of heavy metals did not differ significantly, Triton X-100 + EDTA was more efficient in removing PAHs. Results showed that after 21 pore volume flushing of enhancing solution (Triton X-100 7.5% + EDTA 0.01 M) at flow rate of 0.534 mL min-1 through the column with hydraulic conductivity of 8.5 × 10-5 cm s-1, 54, 47 and 40% of acenaphthene, fluorene, and fluoranthene were removed simultaneously. At the same conditions, 75, 85 and 90% of Pb, Ni and Zn, were also simultaneously removed. Increasing the flow rate of flushing solution decreased the removal efficiency of the contaminants.

Keywords: Column test; Heavy metals; Polycyclic aromatic hydrocarbons; Remediation; Triton X-100; Tween 80.