Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2019 Jul;22(4):353-360.

Selection of the Optimal Puncture Needle for Induction of a Rat Intervertebral Disc Degeneration Model

Affiliations
  • PMID: 31337166
Free article

Selection of the Optimal Puncture Needle for Induction of a Rat Intervertebral Disc Degeneration Model

Jiale Qian et al. Pain Physician. 2019 Jul.
Free article

Abstract

Background: The incidence of intervertebral disc (IVD) degeneration has increased in recent years. A simple, reliable, and reproducible animal model is critical for understanding the underlying mechanisms of IVD degeneration. The caudal discs of rats have been proposed as a common puncture model in which to induce IVD degeneration. However, there is still no consensus on the size of needle to be used.

Objectives: The present study aimed to identify the appropriate needle size to establish an IVD degeneration model.

Study design: A randomized, experimental trial.

Setting: Department of Orthopaedic Surgery, The First Affiliated Hospital of Soochow University, China.

Methods: Validity was verified by magnetic resonance imaging (MRI) and histology.

Results: From T2-weighted MRI imaging and histological examination, the IVD punctured by the 16-gauge needle degenerated acutely one week after the operation, whereas the 26-gauge needle puncture did no harm to the IVD. An 18-gauge needle showed a progressive degeneration in IVD.

Limitations: The observation period was not very long (4 weeks).

Conclusions: An 18-gauge needle can be used to induce IVD degeneration in rats. Therefore, an 18-gauge needle is the optimal selection to establish the degenerative IVD model on rats, whereas the 26-gauge needle failed to cause IVD degeneration. Thus, to study the prevention and treatment of IVD degeneration, a 26-gauge needle can be used for IVD injection of growth factors, plasmids, and drugs. A 16-gauge needle may be used to induce acute disc injury, but not IVD degeneration.

Key words: Low back pain, degenerative intervertebral disc, animal model, puncture needle, rat model, optimal choice.