Intra- and interobserver reliability and agreement in three-dimensional computed tomography measurements of component positions after total knee arthroplasty
- PMID: 31340892
- DOI: 10.1016/j.knee.2019.07.001
Intra- and interobserver reliability and agreement in three-dimensional computed tomography measurements of component positions after total knee arthroplasty
Abstract
Background: Accurate evaluation of the postoperative position of total knee arthroplasty (TKA) components is crucial in the analysis of the association of alignments with clinical outcomes. The aim of this study was to investigate the reliability of measurements of component positions after TKA using three-dimensional computed tomography (3D-CT) reconstruction.
Methods: Two independent orthopedic surgeons (an attending surgeon and a fellow) examined 30 knees after primary TKA. The coronal, sagittal, and rotational positions of the femoral and tibial components were measured twice at an interval of six weeks on 3D-CT images reconstructed using ZedKnee software. Mean intra- and interobserver differences of measured angles were calculated, and the intra- and interobserver reliability was determined using intraclass correlation coefficients (ICCs), with agreement assessed by Bland-Altman analysis.
Results: The mean intraobserver difference between alignment measurements for femoral and tibial components was <2° (range 0.23-1.17°) and the mean interobserver difference was <1° (range 0.22-0.97°). The intra- and interobserver ICCs were >0.8 for all component positions. The only systematic bias found in the intra- and interobserver agreements occurred for the sagittal position of the femoral component.
Conclusion: Three-dimensional-CT measurements of component positions after TKA showed good intra- and interobserver reliability for the femoral and tibial components in coronal, sagittal and rotational positions. The intra- and interobserver agreements were favorable for all but the sagittal position of the femur. These results suggest that 3D-CT can be used to evaluate the alignment of all TKA components except for the sagittal position of the femur.
Keywords: 3D-CT; Agreement; Component position; Intra- and interobserver reliability; Three-dimensional measurement; Total knee arthroplasty.
Copyright © 2019 Elsevier B.V. All rights reserved.
Similar articles
-
Inter-observer reliability of measurements performed on digital long-leg standing radiographs and assessment of validity compared to 3D CT-scan.Knee. 2016 Jan;23(1):20-4. doi: 10.1016/j.knee.2015.08.008. Epub 2015 Dec 31. Knee. 2016. PMID: 26746040
-
Comparing inter- and intraobserver reliability between two-dimensional and three-dimensional measurements in the tibial component position of unicompartmental knee arthroplasty.Acta Orthop Belg. 2023 Jun;89(2):316-325. doi: 10.52628/89.2.10553. Acta Orthop Belg. 2023. PMID: 37924549
-
Partially loaded plain radiographic measurement to evaluate rotational alignment in total knee arthroplasty.Int Orthop. 2016 Dec;40(12):2519-2526. doi: 10.1007/s00264-016-3247-7. Epub 2016 Jul 22. Int Orthop. 2016. PMID: 27447464 Clinical Trial.
-
How to assess femoral and tibial component rotation after total knee arthroplasty with computed tomography: a systematic review.Knee Surg Sports Traumatol Arthrosc. 2016 Nov;24(11):3517-3528. doi: 10.1007/s00167-016-4325-5. Epub 2016 Sep 21. Knee Surg Sports Traumatol Arthrosc. 2016. PMID: 27655141
-
Intra- and postoperative assessment of femoral component rotation in total knee arthroplasty: an EKA knee expert group clinical review.Knee Surg Sports Traumatol Arthrosc. 2021 Mar;29(3):772-782. doi: 10.1007/s00167-020-06006-4. Epub 2020 Apr 30. Knee Surg Sports Traumatol Arthrosc. 2021. PMID: 32350578
Cited by
-
Self-aligned Technique for Tibial Component Placement in Total Knee Arthroplasty Lessening Rotational Malalignment in Measured Resection and Gap-Balancing Techniques.Clin Orthop Surg. 2023 Aug;15(4):597-605. doi: 10.4055/cios22106. Epub 2022 Nov 30. Clin Orthop Surg. 2023. PMID: 37529181 Free PMC article.
-
Impact of implant positions in total knee arthroplasty on the postoperative knee kinematics of tibial rotation.J Orthop. 2024 Jun 22;58:24-28. doi: 10.1016/j.jor.2024.06.025. eCollection 2024 Dec. J Orthop. 2024. PMID: 39045510
-
Are asymmetric designs of tibial components superior to their symmetric counterparts for constrained condylar total knee arthroplasty using metal block augmentation?Arthroplasty. 2024 Nov 4;6(1):54. doi: 10.1186/s42836-024-00277-9. Arthroplasty. 2024. PMID: 39491023 Free PMC article.
-
Association between pre- and postoperative rotational mismatches of the femorotibial components and bones in bi-cruciate retaining and posterior stabilized total knee arthroplasty.Sci Rep. 2023 Sep 9;13(1):14902. doi: 10.1038/s41598-023-42243-6. Sci Rep. 2023. PMID: 37689778 Free PMC article.
-
3-dimensional computer tomography is more accurate than traditional long-leg radiographs in the planning and evaluation of coronal alignment in total knee arthroplasty: a prospective study on 121 knees.Acta Orthop. 2023 Oct 26;94:530-536. doi: 10.2340/17453674.2023.19695. Acta Orthop. 2023. PMID: 37882334 Free PMC article.