. 2019 Oct;26(5):1102-1110.
doi: 10.1016/j.knee.2019.07.001. Epub 2019 Jul 21.

Intra- and interobserver reliability and agreement in three-dimensional computed tomography measurements of component positions after total knee arthroplasty

Affiliations

Intra- and interobserver reliability and agreement in three-dimensional computed tomography measurements of component positions after total knee arthroplasty

Kensuke Yoshino et al. Knee. 2019 Oct.

Abstract

Background: Accurate evaluation of the postoperative position of total knee arthroplasty (TKA) components is crucial in the analysis of the association of alignments with clinical outcomes. The aim of this study was to investigate the reliability of measurements of component positions after TKA using three-dimensional computed tomography (3D-CT) reconstruction.

Methods: Two independent orthopedic surgeons (an attending surgeon and a fellow) examined 30 knees after primary TKA. The coronal, sagittal, and rotational positions of the femoral and tibial components were measured twice at an interval of six weeks on 3D-CT images reconstructed using ZedKnee software. Mean intra- and interobserver differences of measured angles were calculated, and the intra- and interobserver reliability was determined using intraclass correlation coefficients (ICCs), with agreement assessed by Bland-Altman analysis.

Results: The mean intraobserver difference between alignment measurements for femoral and tibial components was <2° (range 0.23-1.17°) and the mean interobserver difference was <1° (range 0.22-0.97°). The intra- and interobserver ICCs were >0.8 for all component positions. The only systematic bias found in the intra- and interobserver agreements occurred for the sagittal position of the femoral component.

Conclusion: Three-dimensional-CT measurements of component positions after TKA showed good intra- and interobserver reliability for the femoral and tibial components in coronal, sagittal and rotational positions. The intra- and interobserver agreements were favorable for all but the sagittal position of the femur. These results suggest that 3D-CT can be used to evaluate the alignment of all TKA components except for the sagittal position of the femur.

Keywords: 3D-CT; Agreement; Component position; Intra- and interobserver reliability; Three-dimensional measurement; Total knee arthroplasty.