Comparison of Macintosh Laryngoscopy in Bed-up-Head-Elevated Position With GlideScope Laryngoscopy: A Randomized, Controlled, Noninferiority Trial
- PMID: 31348051
- DOI: 10.1213/ANE.0000000000004349
Comparison of Macintosh Laryngoscopy in Bed-up-Head-Elevated Position With GlideScope Laryngoscopy: A Randomized, Controlled, Noninferiority Trial
Abstract
Background: Approximately half of all difficult tracheal intubations (DTIs) are unanticipated; hence, proper positioning during intubation is critical to increase the likelihood of success. The bed-up-head-elevated (BUHE) intubation position has been shown to improve laryngeal view, reduce airway complications, and prolong safe apneic time during intubation. In this study, we sought to determine whether the BUHE intubation position is noninferior to Glidescope (GLSC)-assisted intubation with regard to laryngeal exposure.
Methods: A total of 138 American Society of Anesthesiologists (ASA) I to III patients were randomly assigned into 2 groups and underwent baseline laryngoscopy in the sniffing position. Group BUHE patients (n = 69) were then intubated in the BUHE position, while group GLSC patients (n = 69) were intubated using GLSC laryngoscopy. Laryngeal exposure was measured using Percentage of Glottic Opening (POGO) score and Cormack-Lehane (CL) grading, and noninferiority will be declared if the difference in mean POGO scores between both groups do not exceed -15% at the lower limit of a 98% confidence interval (CI). Secondary outcomes measured included time required for intubation (TRI), number of intubation attempts, use of airway adjuncts, effort during laryngoscopy, and complications during intubation.
Results: Mean POGO score in group BUHE was 80.14% ± 22.03%, while in group GLSC it was 86.45% ± 18.83%, with a mean difference of -6.3% (98% CI, -13.2% to 0.6%). In both groups, there was a significant improvement in mean POGO scores when compared to baseline laryngoscopy in the sniffing position (group BUHE, 25.8% ± 4.7%; group GLSC, 30.7% ± 6.8%) (P < .0001). The mean TRI was 36.23 ± 14.41 seconds in group BUHE, while group GLSC had a mean TRI of 44.33 ± 11.53 seconds (P < .0001). In patients with baseline CL 3 grading, there was no significant difference between mean POGO scores in both groups (group BUHE, 49.2% ± 19.6% versus group GLSC, 70.5% ± 29.7%; P = .054).
Conclusions: In the general population, BUHE intubation position provides a noninferior laryngeal view to GLSC intubation. The laryngeal views obtained in both approaches were superior to the laryngeal view obtained in the sniffing position. In view of the many advantages of the BUHE position for intubation, the lack of proven adverse effects, the simplicity, and the cost-effectiveness, we propose that clinicians should consider the BUHE position as the standard intubation position for the general population.
Trial registration: ClinicalTrials.gov NCT03357679.
Comment in
-
Noninferiority and Equivalence Trials in Medical Research.Anesth Analg. 2020 Jul;131(1):208-209. doi: 10.1213/ANE.0000000000004783. Anesth Analg. 2020. PMID: 32541592 No abstract available.
-
A New Standard Intubating Position?Anesth Analg. 2021 Feb 1;132(2):e33. doi: 10.1213/ANE.0000000000005306. Anesth Analg. 2021. PMID: 33449570 No abstract available.
-
In Response.Anesth Analg. 2021 Feb 1;132(2):e33-e34. doi: 10.1213/ANE.0000000000005307. Anesth Analg. 2021. PMID: 33449571 No abstract available.
Similar articles
-
Comparison of three video laryngoscopy devices to direct laryngoscopy for intubating obese patients: a randomized controlled trial.J Clin Anesth. 2016 Jun;31:71-7. doi: 10.1016/j.jclinane.2015.12.042. Epub 2016 Mar 23. J Clin Anesth. 2016. PMID: 27185681 Clinical Trial.
-
Comparison of glottic views and intubation times in the supine and 25 degree back-up positions.BMC Anesthesiol. 2016 Nov 16;16(1):113. doi: 10.1186/s12871-016-0280-4. BMC Anesthesiol. 2016. PMID: 27852241 Free PMC article. Clinical Trial.
-
Effects of head-elevated position on tracheal intubation using a McGrath MAC videolaryngoscope in patients with a simulated difficult airway: a prospective randomized crossover study.BMC Anesthesiol. 2022 May 30;22(1):166. doi: 10.1186/s12871-022-01706-5. BMC Anesthesiol. 2022. PMID: 35637437 Free PMC article. Clinical Trial.
-
Efficacy and safety of videolaryngoscopy versus direct laryngoscopy in paediatric intubation: A meta-analysis of 27 randomized controlled trials.J Clin Anesth. 2020 Nov;66:109968. doi: 10.1016/j.jclinane.2020.109968. Epub 2020 Jul 6. J Clin Anesth. 2020. PMID: 32645564
-
Effects of sniffing position for tracheal intubation: a meta-analysis of randomized controlled trials.Am J Emerg Med. 2015 Nov;33(11):1606-11. doi: 10.1016/j.ajem.2015.06.049. Epub 2015 Jun 23. Am J Emerg Med. 2015. PMID: 26227445 Review.
Cited by
-
Comparison of intubating conditions in supine (sniffing) and 25° back-up position using channelled and non-channelled video laryngoscopes - A randomised controlled study.Indian J Anaesth. 2023 Dec;67(12):1090-1095. doi: 10.4103/ija.ija_662_23. Epub 2023 Dec 13. Indian J Anaesth. 2023. PMID: 38343674 Free PMC article.
-
Proteus Syndrome, Anticipated Difficult Airway, and 2 Trusted Lieutenants!Turk J Anaesthesiol Reanim. 2022 Dec;50(6):465-466. doi: 10.5152/TJAR.2021.21149. Turk J Anaesthesiol Reanim. 2022. PMID: 36511499 Free PMC article. No abstract available.
-
Effectiveness of preoxygenation during endotracheal intubation in a head-elevated position: a systematic review and meta-analysis of randomized controlled trials.Anaesthesiol Intensive Ther. 2022;54(5):413-424. doi: 10.5114/ait.2022.123197. Anaesthesiol Intensive Ther. 2022. PMID: 36734452 Free PMC article.
-
Respiratory care for the critical patients with 2019 novel coronavirus.Respir Med. 2021 Sep;186:106516. doi: 10.1016/j.rmed.2021.106516. Epub 2021 Jun 21. Respir Med. 2021. PMID: 34218168 Free PMC article. Review.
-
Comparison of a videolaryngoscope with a 3D-printed angled blade and a direct laryngoscope with a Macintosh blade for rapid sequence tracheal intubation: An observational study.Eur J Anaesthesiol. 2024 Dec 1;41(12):934-937. doi: 10.1097/EJA.0000000000002058. Epub 2024 Sep 5. Eur J Anaesthesiol. 2024. PMID: 39238349 Free PMC article. No abstract available.
Publication types
MeSH terms
Associated data
LinkOut - more resources
Full Text Sources
Medical