Clinical and Radiological Evaluation of Patients Undergoing Distal Radio Osteosynthesis with Locking Plate-Retrospective Study
- PMID: 31363285
- PMCID: PMC6597432
- DOI: 10.1055/s-0039-1691759
Clinical and Radiological Evaluation of Patients Undergoing Distal Radio Osteosynthesis with Locking Plate-Retrospective Study
Abstract
Objective The objective of the present work was to perform a retrospective study based on the medical files and radiographs of the patients, as well as on the socioeconomic data of the patients submitted to distal radio osteosynthesis with locking plates, evaluating them clinically and radiographically. Methods The postoperative period was evaluated clinically and radiologically in the orthopedics and traumatology clinic service of our hospital between 2016 and 2017. Results In the radiographic evaluation, we found 22 (75.86%) excellent results, 6 (20.69%) good results, and 1 (3.45%) regular result. In the clinical evaluation, the ulnar deviation obtained a mean of 28.40, a standard deviation (SD) of 3.0 and a coefficient of variation of 10.56%. The radial deviations averaged 22.93, with a SD of 2.2 and a coefficient of variation of 9.59%. The range of motion in flexion obtained a mean of 59.43, a SD of 9.86 and a coefficient of variation of 16.59%. The extension obtained a mean of 53.83, a SD of 5.09 and a coefficient of variation of 9.46%. Conclusion We have concluded that there is statistical correlation between clinical and radiographic data, and that the locking plate is a treatment method with a high success rate in the surgical procedure of distal radius fractures.
Keywords: bone; fractures; internal fracture fixation; radius fractures; retrospective studies.
Conflict of interest statement
Figures
References
-
- Arora R, Gabl M, Gschwentner M, Deml C, Krappinger D, Lutz M. A comparative study of clinical and radiologic outcomes of unstable colles type distal radius fractures in patients older than 70 years: nonoperative treatment versus volar locking plating. J Orthop Trauma. 2009;23(04):237–242. - PubMed
-
- O'Neill T W, Cooper C, Finn J D, Lunt M, Purdie D, Reid D M et al.Incidence of distal forearm fracture in British men and women. Osteoporos Int. 2001;12(07):555–558. - PubMed
-
- Liporace F A, Adams M R, Capo J T, Koval K J. Distal radius fractures. J Orthop Trauma. 2009;23(10):739–748. - PubMed
-
- Osada D, Viegas S F, Shah M A, Morris R P, Patterson R M. Comparison of different distal radius dorsal and volar fracture fixation plates: a biomechanical study. J Hand Surg Am. 2003;28(01):94–104. - PubMed
-
- McCall T A, Conrad B, Badman B, Wright T. Volar versus dorsal fixed-angle fixation of dorsally unstable extra-articular distal radius fractures: a biomechanic study. J Hand Surg Am. 2007;32(06):806–812. - PubMed
LinkOut - more resources
Full Text Sources
