Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Observational Study
. 2019 Jul 22:8:124.
doi: 10.1186/s13756-019-0581-8. eCollection 2019.

Incidence of peripheral intravenous catheter failure among inpatients: variability between microbiological data and clinical signs and symptoms

Affiliations
Observational Study

Incidence of peripheral intravenous catheter failure among inpatients: variability between microbiological data and clinical signs and symptoms

Ian Blanco-Mavillard et al. Antimicrob Resist Infect Control. .

Abstract

Background: Peripheral intravenous catheters (PIVCs) are the most widely used invasive devices among inpatients. Catheter-related bloodstream infections (CRBSI) are serious yet preventable events for patients. Although the contribution of PIVCs towards these infections is gradually being recognised, its role in the Spanish setting is yet to be determined. We aimed to estimate the rate and incidence of PIVC failure at Manacor hospital (Spain) as baseline within a wider quality improvement initiative.

Methods: Tips from all PIVC removed during December 2017 and January 2018 in hospital wards were cultured semiquantitatively. The study population included all PIVCs inserted in adult patients admitted to any of three medical and one surgical wards, emergency department, critical care unit and operating rooms. Clinical, microbiological and ward information was collected by clinical researchers for each PIVC from insertion to removal on the study sites. CRBSI was defined per international guidelines (i.e., Centers for Disease Control and Prevention, USA). Data was analysed descriptively.

Results: Seven hundred and eleven tips were cultured, with 41.8% (297/711) reported as PIVC failure. The PIVC failure rate density-adjusted incidence for hospital length of stay (HLOS) was 226.2 PIVC failure/1000 HLOS. 5.8% (41/711) tips yielded positive isolates, with most frequent microorganisms Staphylococcus spp (S. epidermidis 29/41, 70.7%, S. aureus 2/41, 4.9%, S. hominis 2/41, 4.9%), and Acinetobacter baumannii (1/41, 2.4%). One S. aureus isolate was methicillin-resistant. 53.6% (22/41) positive cultures were obtained from patients with local signs and symptoms compatible with catheter-related infection (CRI), 2.4% (1/41) were compatible with CRBSI type 2 and that clinical signs improve within 48 h of catheter removal (density-adjusted incidence for hospital stays of 16.7 PIVC-CRI/1000 hospital-stays and 0.76 PVC-BSI/1000 hospital-stays respectively) and no patients were diagnosed CRBSI type 3 with a bacterial growth concordant in tip and blood cultures. Most cases responded favourably to catheter removal and management.

Conclusions: Our findings show that almost 42% PIVCs resulted in unplanned removal, amplifying the importance in terms of morbidity, mortality and patient safety. A high number of positive tip cultures without clinical signs and symptoms was observed. We underpin the importance to remove unnecessary PIVCs for the prevention of CRBSI.

Keywords: Adverse events; Catheter failure; Catheter-related bloodstream infections; Peripheral intravenous catheter; Vascular access device.

PubMed Disclaimer

Conflict of interest statement

Competing interestsThe authors declare that they have no competing interests.

Figures

Fig. 1
Fig. 1
Flow chart. PIVC Failure

References

    1. Alexandrou E, Ray-Barruel G, Carr PJ, Frost SA, Inwood S, Higgins N, et al. Use of short peripheral intravenous catheters: characteristics, management, and outcomes worldwide. J Hosp Med. 2018;13. Available from. 10.12788/jhm.3039. - PubMed
    1. Zingg W, Cartier V, Inan C, Touveneau S, Theriault M, Gayet-Ageron A, et al. Hospital-wide multidisciplinary, multimodal intervention Programme to reduce central venous catheter-associated bloodstream infection. PLoS One. 2014;9:e93898. doi: 10.1371/journal.pone.0093898. - DOI - PMC - PubMed
    1. European Centre for Disease Prevention and Control. Surveillance report: point prevalence survey of healthcare associated infections and antimicrobial use in European acute care hospitals. Stockholm: ECDC, 2013.; Available from: http://ecdc.europa.eu/en/publications/Publications/healthcare-associated....
    1. Helm Robert E., Klausner Jeffrey D., Klemperer John D., Flint Lori M., Huang Emily. Accepted but Unacceptable. Journal of Infusion Nursing. 2015;38(3):189–203. doi: 10.1097/NAN.0000000000000100. - DOI - PubMed
    1. Pujol M., Hornero A., Saballs M., Argerich M.J., Verdaguer R., Cisnal M., Peña C., Ariza J., Gudiol F. Clinical epidemiology and outcomes of peripheral venous catheter-related bloodstream infections at a university-affiliated hospital. Journal of Hospital Infection. 2007;67(1):22–29. doi: 10.1016/j.jhin.2007.06.017. - DOI - PubMed

Publication types

MeSH terms