Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2019 Aug 1;47(2):E6.
doi: 10.3171/2019.5.FOCUS18582.

Evaluation of neurosurgical implant infection rates and associated pathogens: evidence from 1118 postoperative infections

Affiliations

Evaluation of neurosurgical implant infection rates and associated pathogens: evidence from 1118 postoperative infections

Ying Chen et al. Neurosurg Focus. .

Abstract

Objective: Various implanted materials are used in neurosurgery; however, there remains a lack of pooled data on infection rates (IRs) and infective bacteria over past decades. The goal of this study was to investigate implant infections in neurosurgical procedures in a longitudinal retrospective study and to evaluate the IRs of neurosurgically implanted materials and the distribution of pathogenic microorganisms.

Methods: A systematic literature search was conducted using PubMed and Web of Science databases for the time period between 1968 and 2018. Neurosurgical implant infections were studied in 5 subgroups, including operations or diseases, implanted materials, bacteria, distribution by country, and time periods, which were obtained from the literature and statistically analyzed. In this meta-analysis, statistical heterogeneity across studies was tested by using p values and I2 values between studies of associated pathogens. Egger's test was used for assessing symmetries of funnel plots with Stata 11.0 software. Methodological quality was assessed to judge the risk of bias according to the Cochrane Handbook.

Results: A total of 22,971 patients from 227 articles satisfied the study's eligibility criteria. Of these, 1118 cases of infection were reported, and the overall IR was 4.87%. In this study, the neurosurgical procedures or disorders with the top 3 IRs included craniotomy (IR 6.58%), cranioplasty (IR 5.89%), and motor movement disorders (IR 5.43%). Among 13 implanted materials, the implants with the top 3 IRs included polypropylene-polyester, titanium, and polyetheretherketone (PEEK), which were 8.11%, 8.15%, and 7.31%, respectively. Furthermore, the main causative pathogen was Staphylococcus aureus and the countries with the top 3 IRs were Denmark (IR 11.90%), Korea (IR 10.98%), and Mexico (IR 9.26%). Except for the low IR from 1998 to 2007, the overall implant IR after neurosurgical procedures was on the rise.

Conclusions: In this study, the main pathogen in neurosurgery was S. aureus, which can provide a certain reference for the clinic. In addition, the IRs of polypropylene-polyester, titanium, and PEEK were higher than other materials, which means that more attention should be paid to them. In short, the total IR was high in neurosurgical implants and should be taken seriously.

Keywords: HA = hydroxyapatite; IR = infection rate; PEEK = polyetheretherketone; PMMA = polymethylmethacrylate; SSI = surgical site infection; cerebral surgery; cranioplasty; infection rate; infective bacteria; neurosurgery.

PubMed Disclaimer

Publication types

MeSH terms

LinkOut - more resources