. 2019 Jul-Sep;53(3):169-180.
doi: 10.1016/j.rh.2019.05.001. Epub 2019 Jul 9.

[Effectiveness of the use of standing devices in the prevention of hip dislocation in children and adolescents with spastic cerebral palsy, GMFCS III, IV and V. A systematic review]

[Article in Spanish]
Affiliations

[Effectiveness of the use of standing devices in the prevention of hip dislocation in children and adolescents with spastic cerebral palsy, GMFCS III, IV and V. A systematic review]

[Article in Spanish]
N Pérez Ramírez et al. Rehabilitacion (Madr). 2019 Jul-Sep.

Abstract

The standing devices are used as a preventive therapy for hip dislocation in patients with cerebral palsy. This review seeks to assess the effectiveness of standing devices in the prevention of hip dislocation of patients under 18 years old with a diagnosis of spastic cerebral palsy, GMFCS III-V. A systematic search was conducted in 10 biomedical databases, selecting randomized, quasi-experimental clinical trials and cohort studies. The use of standing devices with physical therapy, orthosis and/or soft tissue surgeries was compared. The percentage of migration of the femoral head was considered as the main result. The risk of bias was assessed using the Rob 2.0 and Robins I guidelines. As a result of the analysis of 6 primary studies, it is obtained that the use of standing devices maintained the percentage of migration of the femoral head within normal limits (MP:13-23%, p<.01), increased vertebral trabecular volumetric bone mineral density (8.16mg/cm3, p=.01), bone mineral content (p=.010) and hamstring muscle length (phase B1 p<.01 and B2 p=.03). However, the risk of bias in these studies was categorized as of some concern to moderate. In conclusion, it is stated that there is limited evidence of the effectiveness of the use of standing devices in the prevention of hip dislocation in the study population, due to the methodological heterogeneity and risk of bias of the included studies. A greater number of studies with a high level of evidence are required in order to generate a recommendation for its use. Registration in PROSPERO: CRD42018087641.

Keywords: Bipedestador; Cerebral palsy; Displasia de cadera; Hip dislocation; Hip displacement; Luxación de cadera; Parálisis cerebral; Revisión sistemática; Standing device; Systematic review.