Update on the usefulness of optical coherence tomography in assessing the iridocorneal angle
- PMID: 31371112
- DOI: 10.1016/j.oftal.2019.06.007
Update on the usefulness of optical coherence tomography in assessing the iridocorneal angle
Abstract
The iridocorneal angle, due to its implications in the physiopathology of aqueous humour drainage, is a fundamental structure of the anterior chamber. Anterior segment optical coherence tomography is a rapid and non-invasive technique that obtains images in vivo. The high resolution allows it to analyse the normal anatomy of the angle, any alterations, and the changes that occur after different therapeutic interventions. Anterior segment optical coherence tomography technology has evolved to provide images that allow the identification and quantification of the angular structures in healthy subjects and in glaucoma patients, and especially the trabecular meshwork and the Schlemm's canal. It also enables the angle width to be quantified, with some objective parameters that have been standardised in recent years, such as the trabecular-iris angle, the angle opening distance, and the trabecular-iris area. This technique has multiple uses in the study of the different mechanisms of angle closure, the evaluation of changes after a laser peripheral iridotomy or iridoplasty after cataract surgery, as well as after the implantation of phakic lenses.
Keywords: Abertura angular; Angle width; Canal de Schlemm; Glaucoma; Iridocorneal angle; Malla trabecular; Optical coherence tomography; Schlemm's canal; Tomografía de coherencia óptica; Trabecular meshwork; Ángulo iridocorneal.
Copyright © 2019 Sociedad Española de Oftalmología. Publicado por Elsevier España, S.L.U. All rights reserved.
Similar articles
-
Identification of iridocorneal angle structures assessed by Fourier domain optical coherence tomography.Arch Soc Esp Oftalmol. 2016 Feb;91(2):74-80. doi: 10.1016/j.oftal.2015.10.007. Epub 2015 Dec 2. Arch Soc Esp Oftalmol. 2016. PMID: 26652971
-
In Vivo Assessment of the Pediatric Trabecular Meshwork, Schlemm Canal, and Iridocorneal Angle Using Overhead-Mounted Optical Coherence Tomography.Am J Ophthalmol. 2025 Jan;269:402-408. doi: 10.1016/j.ajo.2024.09.001. Epub 2024 Sep 17. Am J Ophthalmol. 2025. PMID: 39265692
-
Dynamic Changes in Schlemm Canal and Iridocorneal Angle Morphology During Accommodation in Children With Healthy Eyes: A Cross-Sectional Cohort Study.Invest Ophthalmol Vis Sci. 2018 Jul 2;59(8):3497-3502. doi: 10.1167/iovs.17-23189. Invest Ophthalmol Vis Sci. 2018. PMID: 30025073
-
Anterior Segment Optical Coherence Tomography Changes to the Anterior Chamber Angle in the Short-term following Laser Peripheral Iridoplasty.J Curr Glaucoma Pract. 2014 Jan-Apr;8(1):1-6. doi: 10.5005/jp-journals-10008-1152. Epub 2014 Jan 16. J Curr Glaucoma Pract. 2014. PMID: 26997799 Free PMC article. Review.
-
[Imaging of the iridocorneal angle in glaucoma].J Fr Ophtalmol. 2013 Apr;36(4):378-83. doi: 10.1016/j.jfo.2013.01.006. Epub 2013 Mar 29. J Fr Ophtalmol. 2013. PMID: 23541534 Review. French.
Cited by
-
Swept-source optical coherence tomography in ocular surface diseases: anterior segment analysis repeatability and its limits.Front Med (Lausanne). 2024 Aug 2;11:1385294. doi: 10.3389/fmed.2024.1385294. eCollection 2024. Front Med (Lausanne). 2024. PMID: 39156694 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources