Dosimetric comparison of two treatment planning systems for spine SBRT
- PMID: 31376988
- DOI: 10.1016/j.meddos.2019.07.001
Dosimetric comparison of two treatment planning systems for spine SBRT
Abstract
Two commonly used treatment planning systems (TPS) are compared for the planning of spine stereotactic body radiotherapy (SBRT). The main purpose is to highlight relative advantages and disadvantages of each system and propose a methodologic approach for comparisons. Twenty clinical plans were inversely planned with step-and-shoot intensity-modulated radiotherapy (IMRT) each using 9 to 11 beams, referred to as IMRT_P. The prescription dose was 24 Gy in 2 fractions, and the plans were generated following our institutional protocol using the Pinnacle3 v9.2. Each case was replanned using a 2-arc volumetric modulated arc therapy (VMAT) approach, referred as VMAT_P. CT and structure sets were DICOM exported to Monaco v5.10 and planned in 2 different ways: IMRT (IMRT_M) and VMAT (VMAT_M) using the same prescription dose. Dose volume histograms (DVH) and other dose statistics of planning target volumes (PTV) and organ-at-risk (OAR) were analyzed and compared between plans. The gradient index (GI = ratio of 50% isodose volume to prescribed isodose volume) was used to measure dose fall-off outside of the PTV. Another metric - Gradient Index Inner (GIinner = the rate (in Gy/mm) - at which the dose changes from the level of the spinal cord/thecal sac toward the prescription dose) was developed and compared. All plans were considered clinically acceptable by institutional guidelines and achieved all of the OAR dose constraints. VMAT_M and IMRT_M showed comparable dose statistics for the PTV when compared to VMAT_P and IMRT_P, respectively. For IMRT plans, the median GIinner was 1.88 Gy/mm vs 1.52 Gy/mm for IMRT_M and IMRT_P respectively (p< 0.001). All other IMRT metrics were statistically similar except for the PTV maximum dose (Dmax), which was higher for IMRT_M than IMRT_P (median 30.7 Gy vs 29.0 Gy, p< 0.001). For VMAT plans, only PTV Dmin showed a statistical different between VMAT_M and VMAT_P of median 12.7 Gy vs 9.7 Gy (p< 0.001). In terms of beam sequencing parameters, the number of monitor units was statistically higher for VMAT_P compared to VMAT_M (median = 6764 vs 5376) whereas the number of segments for IMRT_M was statistically greater than IMRT_P (median = 155 vs 73). We were able to generate clinically acceptable plans for different types of spine SBRT using 2 different TPS. We used an evaluation strategy involving coverage, conformity, and dose gradient that can compared between TPS.
Keywords: Adaptive planning; Automatic segmentation; Cancer; Head and neck; Radiotherapy.
Copyright © 2019 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.
Similar articles
-
Treatment plan quality and delivery accuracy assessments on 3 IMRT delivery methods of stereotactic body radiotherapy for spine tumors.Med Dosim. 2019 Spring;44(1):11-14. doi: 10.1016/j.meddos.2017.12.009. Epub 2018 Feb 21. Med Dosim. 2019. PMID: 29429794
-
Volumetric-modulated arc therapy vs. c-IMRT in esophageal cancer: a treatment planning comparison.World J Gastroenterol. 2012 Oct 7;18(37):5266-75. doi: 10.3748/wjg.v18.i37.5266. World J Gastroenterol. 2012. PMID: 23066322 Free PMC article.
-
Volumetric modulated arc therapy treatment planning of thoracic vertebral metastases using stereotactic body radiotherapy.J Appl Clin Med Phys. 2018 Mar;19(2):54-61. doi: 10.1002/acm2.12252. Epub 2018 Jan 19. J Appl Clin Med Phys. 2018. PMID: 29349867 Free PMC article.
-
Dosimetric comparison between Intensity Modulated Radiation Therapy (IMRT) vs dual arc Volumetric Arc Therapy (VMAT) for nasopharyngeal cancer (NPC): Systematic review and meta-analysis.J Med Imaging Radiat Sci. 2023 Mar;54(1):167-177. doi: 10.1016/j.jmir.2022.10.195. Epub 2022 Nov 29. J Med Imaging Radiat Sci. 2023. PMID: 36456460
-
Planning System-dependent Recommendations of Intensity-modulated Technique for Breast Radiotherapy: A Literature Review-based Adaptation and Institutional Dosimetric Experience from a Large-volume Tertiary Cancer Care Hospital.J Med Phys. 2023 Jul-Sep;48(3):221-229. doi: 10.4103/jmp.jmp_51_23. Epub 2023 Sep 18. J Med Phys. 2023. PMID: 37969141 Free PMC article. Review.
Cited by
-
Optimizing Motion Management and Baseline Shifts in Magnetic Resonance-Guided Spine Stereotactic Body Radiation Therapy.Cancers (Basel). 2025 Aug 19;17(16):2697. doi: 10.3390/cancers17162697. Cancers (Basel). 2025. PMID: 40867326 Free PMC article.
-
Dosimetric analysis of MR-LINAC treatment plans for salvage spine SBRT re-irradiation.J Appl Clin Med Phys. 2022 Oct;23(10):e13752. doi: 10.1002/acm2.13752. Epub 2022 Aug 25. J Appl Clin Med Phys. 2022. PMID: 36004700 Free PMC article.
-
The dosimetric impact of titanium implants in spinal SBRT using four commercial treatment planning algorithms.J Appl Clin Med Phys. 2023 Oct;24(10):e14070. doi: 10.1002/acm2.14070. Epub 2023 Aug 4. J Appl Clin Med Phys. 2023. PMID: 37540084 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources