^{27}Al^{+} Quantum-Logic Clock with a Systematic Uncertainty below 10^{-18}
- PMID: 31386450
- DOI: 10.1103/PhysRevLett.123.033201
^{27}Al^{+} Quantum-Logic Clock with a Systematic Uncertainty below 10^{-18}
Erratum in
-
Erratum: ^{27}Al^{+} Quantum-Logic Clock with a Systematic Uncertainty below 10^{-18} [Phys. Rev. Lett. 123, 033201 (2019)].Phys Rev Lett. 2023 Aug 4;131(5):059901. doi: 10.1103/PhysRevLett.131.059901. Phys Rev Lett. 2023. PMID: 37595250
Abstract
We describe an optical atomic clock based on quantum-logic spectroscopy of the ^{1}S_{0}↔^{3}P_{0} transition in ^{27}Al^{+} with a systematic uncertainty of 9.4×10^{-19} and a frequency stability of 1.2×10^{-15}/sqrt[τ]. A ^{25}Mg^{+} ion is simultaneously trapped with the ^{27}Al^{+} ion and used for sympathetic cooling and state readout. Improvements in a new trap have led to reduced secular motion heating, compared to previous ^{27}Al^{+} clocks, enabling clock operation with ion secular motion near the three-dimensional ground state. Operating the clock with a lower trap drive frequency has reduced excess micromotion compared to previous ^{27}Al^{+} clocks. Both of these improvements have led to a reduced time-dilation shift uncertainty. Other systematic uncertainties including those due to blackbody radiation and the second-order Zeeman effect have also been reduced.