Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2019 Sep 3;91(17):10988-10995.
doi: 10.1021/acs.analchem.9b01027. Epub 2019 Aug 19.

Antibiotic Susceptibility Test with Surface-Enhanced Raman Scattering in a Microfluidic System

Antibiotic Susceptibility Test with Surface-Enhanced Raman Scattering in a Microfluidic System

Kai-Wei Chang et al. Anal Chem. .

Abstract

Antibiotic susceptibility test (AST) is essential in clinical diagnosis of serious bacterial infection, such as sepsis, while it typically takes 2-5 days for sample culture, antibiotic treatment, and reading result. Detecting metabolites secreted from bacteria with surface-enhanced Raman scattering (SERS) enables rapid determination of antibiotic susceptibility, reducing the AST time to 1-2 days. However, it still requires 1 day of culture time to obtain sufficient quantity of bacteria for sample washing, bacterial extraction, and antibiotic treatment. Additionally, the whole procedure, manually performed in open environment, often suffers from contamination and human error. To address the above problems, a microfluidic system integrating membrane filtration and the SERS-active substrate (MF-SERS) was developed to perform on-chip bacterial enrichment, metabolite collection, and in situ SERS measurements for antibiotic susceptibility test. Using Escherichia coli as the prototype bacterium, the lowest SERS detection limit of bacterial concentration of the MF-SERS system is 103 CFU/mL, which is 4 orders of magnitude lower than that using centrifugation-purification procedure, significantly shortening the bacterial culture time. The bacteria and secreted metabolites are enclosed during bacterial trapping, metabolite filtration, and SERS detection, thus minimizing possible contamination and human errors. Finally, the successful demonstration of AST on E. coli with a concentration of 103 CFU/mL is presented. Overall, the MF-SERS system with a miniature size and well-confined microenvironment allows the integration of multiple bacteria processes for bacterial enrichment, culture, and determination of AST.

PubMed Disclaimer

Similar articles

Cited by

Publication types

MeSH terms