. 2020 Mar;71(3):208-216.
doi: 10.1177/0003319719866958. Epub 2019 Aug 6.

Applicability of Transcutaneous Oxygen Tension Measurement in the Assessment of Chronic Limb-Threatening Ischemia

Affiliations

Applicability of Transcutaneous Oxygen Tension Measurement in the Assessment of Chronic Limb-Threatening Ischemia

Bernard Leenstra et al. Angiology. 2020 Mar.

Abstract

Transcutaneous oxygen tension measurement (TcPO2) is widely applied for the evaluation of chronic limb-threatening ischemia (CLTI). Nevertheless, studies that focused on the clinical value of TcPO2 have shown varying results. We identified factors that potentially play a role in TcPO2 measurement variation such as probe placement, probe temperature, and the use of a reference probe. In this review of the current literature, we assessed the application of these factors. A systematic search was conducted. Parameters that were assessed were probe placement, probe temperature, and mentioning and/or use of a reference probe. In total, 36 articles were eligible for analysis. In 24 (67%) studies, probes were placed on specific anatomical locations. Seven (19%) studies placed probes, regardless of the location of the ulcer, adjacent to an ischemic lesion or ulcer (perilesion). Selected temperature setting of the probe differed; in 18 (50%), a default probe temperature of 44°C was selected, and in 13 (36%), a different temperature was selected. In 31 (84%) studies, the use of a reference probe was not reported. Transcutaneous oxygen tension measurement is applied diversely in patients with CLTI. Homogeneity in TcPO2 protocols is warranted for reliable clinical application and to compare future TcPO2 research.

Keywords: TcPO2; chronic limb-threatening ischemia; critical limb ischemia; diabetes; diabetic foot ischemia; peripheral arterial disease; transcutaneous oximetry.

PubMed Disclaimer

Conflict of interest statement

Declaration of Conflicting Interests: The author(s) declared no potential conflicts of interest with respect to the research, authorship, and/or publication of this article.

Figures

Figure 1.
Figure 1.
Overview of study selection.

Similar articles

Cited by

References

    1. Hiramoto JS, Teraa M, de Borst GJ, Conte MS. Interventions for lower extremity peripheral artery disease. Nat Rev Cardiol. 2018;15(6):332–50. - PubMed
    1. Teraa M, Conte MS, Moll FL, Verhaar MC. Critical limb Ischemia: current trends and future directions. J Am Heart Assoc. 2016;5(2):e002938. - PMC - PubMed
    1. Fowkes FG, Rudan D, Rudan I. et al. Comparison of global estimates of prevalence and risk factors for peripheral artery disease in 2000 and 2010: a systematic review and analysis. Lancet. 2013;382(9901):1329–40. - PubMed
    1. Rosfors S, Kanni L, Nystrom T. The impact of transcutaneous oxygen pressure measurement in patients with suspected critical lower limb ischemia. Int Angiol. 2016;35(5):492–7. - PubMed
    1. Arsenault KA, McDonald J, Devereaux PJ, Thorlund K, Tittley JG, Whitlock RP. The use of transcutaneous oximetry to predict complications of chronic wound healing: a systematic review and meta-analysis. Wound Repair Regen. 2011;19(6):657–63. - PubMed

MeSH terms