Patient-Specific Organ and Effective Dose Estimates in Adult Oncologic CT
- PMID: 31414882
- PMCID: PMC7393764
- DOI: 10.2214/AJR.19.21197
Patient-Specific Organ and Effective Dose Estimates in Adult Oncologic CT
Abstract
OBJECTIVE. Patient-specific organ and effective dose provides essential information for CT protocol optimization. However, such information is not readily available in the scan records. The purpose of this study was to develop a method to obtain accurate examination- and patient-specific organ and effective dose estimates by use of available scan data and patient body size information for a large cohort of patients. MATERIALS AND METHODS. The data were randomly collected for 1200 patients who underwent CT in a 2-year period. Physical characteristics of the patients and CT technique were processed as inputs for the dose estimator. Organ and effective doses were estimated by use of the inputs and computational human phantoms matched to patients on the basis of sex and effective diameter. Size-based ratios were applied to correct for patient-phantom body size differences. RESULTS. Patients received a mean of 59.9 mGy to the lens of the eye per brain scan, 10.1 mGy to the thyroid per chest scan, 17.5 mGy to the liver per abdomen and pelvis scan, and 19.0 mGy to the liver per body scan. A factor of 2 difference in dose estimates was observed between patients of various habitus. CONCLUSION. Examination- and patient-specific organ and effective doses were estimated for 1200 adult oncology patients undergoing CT. The dose conversion factors calculated facilitate rapid organ and effective dose estimation in clinics. Compared with nonspecific dose estimation methods, patient dose estimations with data specific to the patient and examination can differ by a factor of 2.
Keywords: CT; adult patient-specific; effective dose; organ dose; size-specific dose estimate.
Similar articles
-
Patient-specific dose estimation for pediatric chest CT.Med Phys. 2008 Dec;35(12):5821-8. doi: 10.1118/1.3026593. Med Phys. 2008. PMID: 19175138 Free PMC article.
-
Patient size and radiation exposure in thoracic, pelvic, and abdominal CT examinations performed with automatic exposure control.AJR Am J Roentgenol. 2010 Dec;195(6):1342-6. doi: 10.2214/AJR.09.3331. AJR Am J Roentgenol. 2010. PMID: 21098193
-
Patient-specific organ and effective dose estimates in pediatric oncology computed tomography.Phys Med. 2018 Jan;45:146-155. doi: 10.1016/j.ejmp.2017.12.013. Epub 2017 Dec 22. Phys Med. 2018. PMID: 29472080 Free PMC article.
-
Effects of protocol and obesity on dose conversion factors in adult body CT.Med Phys. 2012 Nov;39(11):6550-71. doi: 10.1118/1.4754584. Med Phys. 2012. PMID: 23127050 Free PMC article.
-
NCICT: a computational solution to estimate organ doses for pediatric and adult patients undergoing CT scans.J Radiol Prot. 2015 Dec;35(4):891-909. doi: 10.1088/0952-4746/35/4/891. Epub 2015 Nov 26. J Radiol Prot. 2015. PMID: 26609995
Cited by
-
Improving outcomes in electromagnetic navigation bronchoscopy-guided transbronchial microwave ablation for pulmonary nodules: the role of cone-beam computed tomography.Ther Adv Respir Dis. 2025 Jan-Dec;19:17534666251333287. doi: 10.1177/17534666251333287. Epub 2025 Apr 24. Ther Adv Respir Dis. 2025. PMID: 40269652 Free PMC article.
-
Representative Organ Doses from Computed Tomography (CT) Exams from a Large International Registry.Radiat Res. 2025 Jan 1;203(1):1-9. doi: 10.1667/RADE-24-00178.1. Radiat Res. 2025. PMID: 39689286
-
Assessment of organ and effective doses received by adult patients undergoing computed tomography in three hospitals in Brazzaville, Congo Republic.Radiol Phys Technol. 2022 Dec;15(4):379-386. doi: 10.1007/s12194-022-00678-y. Epub 2022 Sep 3. Radiol Phys Technol. 2022. PMID: 36057745
-
Ionizing radiation exposure after allogeneic hematopoietic cell transplantation.Bone Marrow Transplant. 2022 May;57(5):827-829. doi: 10.1038/s41409-022-01612-x. Epub 2022 Feb 19. Bone Marrow Transplant. 2022. PMID: 35184148 Free PMC article. No abstract available.
References
-
- Murphy MJ, Balter J, Balter S, et al. The management of imaging dose during image-guided radiotherapy: Report of the AAPM Task Group 75. Medical physics 2007; 34:4041–4063 - PubMed
-
- Valentin J, ICRP. Managing patient dose in multi-detector computed tomography(MDCT). ICRP Publication 102. Annals of the ICRP 2007; 37:1–79 - PubMed
-
- ICRP. Radiation Protection in Medicine. ICRP Publication 105. Annals of the ICRP 2007; 37:1–63 - PubMed
-
- ICRP. Radiological Protection in Cone Beam Computed Tomography (CBCT). ICRP Publication 129. Annals of the ICRP 2015; 44 - PubMed
-
- NCRP. Ionizing Radiation Exposure of the Population of the United States In: NCRP Publications. Bethesda, MD, 2009
Publication types
MeSH terms
Substances
Grants and funding