Is Portal Inflow Modulation Always Necessary for Successful Utilization of Small Volume Living Donor Liver Grafts?
- PMID: 31436885
- DOI: 10.1002/lt.25629
Is Portal Inflow Modulation Always Necessary for Successful Utilization of Small Volume Living Donor Liver Grafts?
Abstract
Although the well-accepted lower limit of the graft-to-recipient weight ratio (GRWR) for successful living donor liver transplantation (LDLT) remains 0.80%, many believe grafts with lower GRWR may suffice with portal inflow modulation (PIM), resulting in equally good recipient outcomes. This study was done to evaluate the outcomes of LDLT with small-for-size grafts (GRWR <0.80%). Of 1321 consecutive adult LDLTs from January 2012 to December 2017, 287 (21.7%) had GRWR <0.80%. PIM was performed (hemiportocaval shunt [HPCS], n = 109; splenic artery ligation [SAL], n = 14) in 42.9% patients. No PIM was done if portal pressure (PP) in the dissection phase was <16 mm Hg. Mean age of the cohort was 49.3 ± 9.1 years. Median Model for End-Stage Liver Disease score was 14, and the lowest GRWR was 0.54%. A total of 72 recipients had a GRWR <0.70%, of whom 58 underwent HPCS (1 of whom underwent HPCS + SAL) and 14 underwent no PIM, whereas 215 had GRWR between 0.70% and 0.79%, of whom 51 and 14 underwent HPCS and SAL, respectively. During the same period, 1034 had GRWR ≥0.80% and did not undergo PIM. Small-for-size syndrome developed in 2.8% patients. Three patients needed shunt closure at 1 and 4 weeks and 60 months. The 1-year patient survival rates were comparable. In conclusion, with PIM protocol that optimizes postperfusion PP, low-GRWR grafts can be used for appropriately selected LDLT recipients with acceptable outcomes.
Copyright © 2019 by the American Association for the Study of Liver Diseases.
Comment in
-
Reply.Liver Transpl. 2020 Feb;26(2):306. doi: 10.1002/lt.25665. Epub 2019 Nov 28. Liver Transpl. 2020. PMID: 31644830 No abstract available.
-
Is Portal Inflow Modulation Always Necessary for Successful Utilization of Small Volume Living Donor Liver Grafts?Liver Transpl. 2020 Feb;26(2):304-305. doi: 10.1002/lt.25670. Epub 2019 Nov 25. Liver Transpl. 2020. PMID: 31657516 No abstract available.
-
Is Portal Inflow Modulation Always Necessary for Successful Utilization of Small Volume Living Donor Liver Grafts?Liver Transpl. 2020 Dec;26(12):1667-1668. doi: 10.1002/lt.25810. Epub 2020 Jul 12. Liver Transpl. 2020. PMID: 32488926 No abstract available.
-
Reply.Liver Transpl. 2020 Dec;26(12):1669-1671. doi: 10.1002/lt.25809. Epub 2020 Aug 6. Liver Transpl. 2020. PMID: 32488978 No abstract available.
References
-
- Kiuchi T, Kasahara M, Uryuhara K, Inomata Y, Uemoto S, Asonuma K, et al. Impact of graft size mismatching on graft prognosis in liver transplantation from living donors. Transplantation 1999;67:321-327.
-
- Emond JC, Renz JF, Ferrell LD, Rosenthal P, Lim RC, Roberts JP, et al. Functional analysis of grafts from living donors: implications for the treatment of older recipients. Ann Surg 1996;224:544-552.
-
- Dahm F, Georgiev P, Clavien PA. Small-for-size syndrome after partial liver transplantation: definition, mechanisms of disease and clinical implications. Am J Transplant 2005;5:2605-2610.
-
- Soejima Y, Taketomi A, Yoshizumi T, Uchiyama H, Harada N, Ijichi H, et al. Feasibility of left lobe living donor liver transplantation between adults: an 8-year, single-center experience of 107 cases. Am J Transplant 2006;6(pt 1):1004-1011.
-
- Ogura Y, Hori T, El Moghazy WM, Yoshizawa A, Oike F, Mori A, et al. Portal pressure <15 mm Hg is a key for successful adult living donor liver transplantation utilizing smaller grafts than before. Liver Transpl 2010;16:718-728.
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
Miscellaneous