Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2019 Aug 27;74(8):1019-1028.
doi: 10.1016/j.jacc.2019.06.045.

Stroke Risk in Patients With Atrial Fibrillation Undergoing Electrical Isolation of the Left Atrial Appendage

Affiliations
Free article

Stroke Risk in Patients With Atrial Fibrillation Undergoing Electrical Isolation of the Left Atrial Appendage

Luigi Di Biase et al. J Am Coll Cardiol. .
Free article

Abstract

Background: Loss of contractility leading to stasis of blood flow following left atrial appendage electrical isolation (LAAEI) could lead to thrombus formation.

Objectives: This study evaluated the incidence of thromboembolic events (TE) in post-LAAEI cases "on" and "off" oral anticoagulation (OAC).

Methods: A total of 1,854 consecutive post-LAAEI patients with follow-up transesophageal echocardiography (TEE) performed in sinus rhythm at 6 months to assess left atrial appendage (LAA) function were included in this analysis.

Results: The TEE at 6 months revealed preserved LAA velocity, contractility, and consistent A waves in 336 (18%) and abnormal parameters in the remaining 1,518 patients. In the post-ablation period, all 336 patients with preserved LAA function were off OAC. At long-term follow-up, patients with normal LAA function did not experience any stroke events. Of the 1,518 patients with abnormal LAA contractility, 1,086 remained on OAC, and the incidence of stroke/transient ischemic attack (TIA) in this population was 18 of 1,086 (1.7%), whereas the number of TE events in the off-OAC patients (n = 432) was 72 (16.7%); p < 0.001. Of the 90 patients with stroke, 84 received left atrial appendage occlusion (LAAO) devices. At median 12.4 months (interquartile range: 9.8 to 15.3 months) of device implantation, 2 (2.4%) patients were on OAC because of high stroke risk or personal preference, whereas 81 patients discontinued OAC after LAAO device implantation without any TE events.

Conclusions: LAAEI is associated with a significant risk of stroke that can be effectively reduced by optimal uninterrupted OAC or LAAO devices.

Keywords: LAA function; atrial fibrillation; catheter ablation; left atrial appendage electrical isolation; left atrial appendage occlusion; oral anticoagulant; thromboembolic events.

PubMed Disclaimer

Comment in

Publication types

LinkOut - more resources