Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2019 Oct;58(4):521-528.
doi: 10.1016/j.ejvs.2019.05.003. Epub 2019 Aug 21.

Immediate Impact of Prosthetic Graft Replacement of the Ascending Aorta on Circumferential Strain in the Descending Aorta

Affiliations
Free article

Immediate Impact of Prosthetic Graft Replacement of the Ascending Aorta on Circumferential Strain in the Descending Aorta

Lisa Q Rong et al. Eur J Vasc Endovasc Surg. 2019 Oct.
Free article

Abstract

Objectives: Prosthetic replacement of the ascending aorta (AA) can potentially modify energy propagation to the distal aorta and contribute to adverse aortic remodelling. This preliminary study employed intra-operative transoesophageal echocardiography (TOE) to assess the immediate impact of prosthetic graft replacement of the AA on circumferential strain in the descending aorta.

Methods: Intra-operative TOEs in patients undergoing AA graft replacement were analysed for circumferential strain, fractional area change (FAC), dimensions (end diastolic area [EDA], and end systolic area [ESA]) in the descending aorta immediately before and after graft replacement. Deformation was assessed via global peak circumferential aortic strain (CAS), together with pulse pressure corrected strain, time to peak strain (TTP), and aortic distensibility.

Results: Forty-five patients undergoing AA replacement with prosthetic graft (91% elective) were studied. Following grafting, descending thoracic aortic circumferential strain increased (6.3 ± 2.8% vs. 8.9 ± 3.4%, p = .001) paralleling distensibility (5.7 [3.7-8.6] 10-3 mmHg vs. 8.5 [6.4-12.4] 10-3 mmHg, p < .001). Despite slight increments in post graft left ventricular ejection fraction (LVEF) (52.3 ± 10.8% vs. 55.0 ± 11.9, p < .001), stroke volume was similar (p = .41), and magnitude of increased strain did not correlate with change in stroke volume (r = -.03, p = .86), LVEF (r = .18, p = .28), or pulse pressure (r = .28, p = .06). Descending aortic size (EDA 4 [2.7-4.6] cm2vs. 3.7 [2.5-5] cm2, p = .89; ESA 4.3 [3.2-5.3] cm2vs. 4.5 [3.3-5.8] cm2, p = .14) was similar pre- and post graft. In subgroup analysis, patients with cystic medial necrosis had a significantly higher post procedure CAS than patients with atherosclerotic aneurysms (9.7 ± 3.5% vs. 7.0 ± 2.3%, p = .03).

Conclusions: Prosthetic graft replacement of the AA increases immediate aortic circumferential strain of the descending aorta, particularly in patients with cystic medial necrosis. Our findings suggest that grafts augment energy transfer to the distal aorta, a potential mechanism for progressive distal aortic dilation and/or dissection.

Keywords: Aortic aneurysm; Echocardiography; Prosthetic grafts; Strain.

PubMed Disclaimer

Comment in

MeSH terms

LinkOut - more resources