Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2020 Feb;101(2):69-78.
doi: 10.1016/j.diii.2019.08.002. Epub 2019 Aug 22.

Feasibility of two-dimensional ultrasound shear wave elastography of human fetal lungs and liver: A pilot study

Affiliations
Free article

Feasibility of two-dimensional ultrasound shear wave elastography of human fetal lungs and liver: A pilot study

N Mottet et al. Diagn Interv Imaging. 2020 Feb.
Free article

Abstract

Purpose: The first aim was to evaluate feasibility and reproducibility of 2-dimensional ultrasound (2D) shear wave elastography (SWE) of human fetal lungs and liver between 24 and 34weeks of gestation. The second aim was to model fetal lung-to-liver elastography ratio (LLE ratio) and to assess its variations according to gestational age and maternal administration of corticosteroids.

Material and methods: 2D-SWE examinations were prospectively performed in fetuses of women with an uncomplicated pregnancy (group 1) and fetuses of women with a threatened preterm labor requiring administration of corticosteroids (group 2). Two 2D-SWE examinations were performed at "day 0" and "day 2" in group 1; before and 24hours after a course of corticosteroid in group 2. Three operators performed 2 cycles of 3 measurements on the lung (regions A1, A2, A3) and the liver (regions IV, V, VI). Repeatability and reproducibility of measurements were calculated. The fetal LLE ratio was modeled from the most reproducible regions.

Results: Fifty-five women were enrolled in group 1 and 48 in group 2. For the lung, 8.6% of measurements were considered invalid and 6.9% for the liver. The most reproducible region for the lung was A3 [ICC between 0.70 (95% CI: 0.42-0.85) and 0.78 (95% CI: 0.48-0.90)] and region VI for the liver [ICC between 0.70 (95% CI: 0.40-0.85) and 0.84 (95% CI: 0.60-0.94)]. According to gestational age, a moderate positive linear correlation was found for stiffness values of A3 (R=0.56), V (R=0.46) and VI (R=0.44). LLE ratio values at "day 0" were not different between the two groups but decreased at "day 2" in group 2 (0.2; 95% CI: 0.07-0.34; P<0.001).

Conclusion: Quantitative fetal lung and liver stiffness measurements are possible with 2D-SWE with acceptable reproducibility.

Keywords: Elasticity imaging techniques; Fetal liver; Fetal lung; Shear wave; Sonoelastography.