. 2020 Mar;83(3):795-805.
doi: 10.1002/mrm.27961. Epub 2019 Aug 26.

Navigator-free metabolite-cycled proton spectroscopy of the heart

Affiliations
Free article

Navigator-free metabolite-cycled proton spectroscopy of the heart

Sophie M Peereboom et al. Magn Reson Med. 2020 Mar.
Free article

Abstract

Purpose: Respiratory gating in cardiac water-suppressed (WS) proton spectroscopy leads to long and unpredictable scan times. Metabolite cycling allows to perform frequency and phase correction on the water signal and, hence, offers an approach to navigator-free cardiac spectroscopy with fixed scan time. The objective of the present study was to develop and implement navigator-free metabolite-cycled cardiac proton spectroscopy (MC nonav) and compare it with standard navigator-gated WS (WS nav) and navigator-free WS (WS nonav) measurements for the assessment of triglyceride-to-water ratios (TG/W) and creatine-to-water ratios (CR/W) in the intraventricular septum of the in vivo heart.

Methods: Navigator-free metabolite-cycled spectroscopy was implemented on a clinical 1.5T system. In vivo measurements were performed on 10 young and 5 older healthy volunteers to assess signal-to-noise ratio efficiency as well as TG/W and CR/W and the relative Cramér-Rao lower bounds for CR. The performance of the metabolite-cycled sequence was verified using simulations.

Results: On average, scan times of MC nonav were 3.4 times shorter compared with WS nav, while no significant bias for TG/W was observed (coefficient of variation = 14.0%). signal-to-noise ratio efficiency of both TG and CR increased for MC nonav compared with WS nav. Relative Cramér-Rao lower bounds of CR decreased for MC nonav. Overall spectral quality was found comparable between MC nonav and WS nav, while it was inferior for WS nonav.

Conclusion: Navigator-free metabolite-cycled cardiac proton spectroscopy offers 3.4-fold accelerated assessment of TG/W and CR/W in the heart with preserved spectral quality when compared with navigator-gated WS scans.

Keywords: 1H-MRS; cardiac spectroscopy; creatine; metabolite cycling; respiratory motion compensation; triglyceride.

PubMed Disclaimer

Similar articles

Cited by

References

REFERENCES

    1. van Ewijk PA, Schrauwen-Hinderling VB, Bekkers SCAM, Glatz JFC, Wildberger JE, Kooi ME. MRS: a noninvasive window into cardiac metabolism. NMR Biomed. 2015;28:747-766.
    1. van den Meer RW, Rijzewijk LJ, Diamant M, et al. The ageing male heart: myocardial triglyceride content as independent predictor of diastolic function. Eur Heart J. 2008;29:1516-1522.
    1. van der Meer RW, Hammer S, Lamb HJ, et al. Effects of short-term high-fat, high-energy diet on hepatic and myocardial triglyceride content in healthy men. J Clin Endocrinol Metab. 2008;93:2702-2708.
    1. Ith M, Stettler C, Xu J, Boesch C, Kreis R. Cardiac lipid levels show diurnal changes and long-term variations in healthy human subjects. NMR Biomed. 2014;27:1285-1292.
    1. Neubauer S. The failing heart - An engine out of fuel. N Engl J Med. 2007;356:1140-1151.