Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Multicenter Study
. 2020 May;109(5):549-559.
doi: 10.1007/s00392-019-01538-3. Epub 2019 Aug 26.

Mitral valve leaflet repair with the new PASCAL system: early real-world data from a German multicentre experience

Affiliations
Multicenter Study

Mitral valve leaflet repair with the new PASCAL system: early real-world data from a German multicentre experience

Steffen D Kriechbaum et al. Clin Res Cardiol. 2020 May.

Abstract

Aims: To examine the clinical experience and practical use of the PASCAL transcatheter valve repair system (Edwards Lifesciences, Irvine, CA, USA) and to report some of the first clinical results.

Methods and results: A total of 18 consecutive patients with severe, symptomatic mitral regurgitation (MR) were included in this German multicentre registry. All patients underwent clinical, echocardiographic, and laboratory assessment prior to the PASCAL procedure and before hospital discharge. MR was classified as functional in 6 patients, degenerative in 2, and combined in 10. All except one received a single PASCAL implant. The preprocedural severe MR present in all patients was reduced: grade 0 in 4 (22.2%), grade I in 11 (61.1%), grade II in 3 (16.7%). The v-wave was significantly reduced from 31.7 ± 9.5 to 18 ± 7.7 mmHg (p < 0.001). Independent leaflet capture, performed in 4 (22.2%) of the patients, wide clasps, and the 10-mm central spacer are features of the PASCAL device to optimize mitral leaflet repair. There were no periprocedural complications.

Conclusion: PASCAL is a safe and effective mitral valve repair device for the treatment of severe MR. Device-specific features allow valve repair tailored to the individual anatomy of the underlying mitral pathology in each patient.

Keywords: Leaflet repair; Mitral regurgitation; Mitral valve disease; Mitral valve repair.

PubMed Disclaimer

References

    1. J Am Coll Cardiol. 2015 Mar 31;65(12):1231-1248 - PubMed
    1. Clin Res Cardiol. 2018 Dec;107(12):1087-1102 - PubMed
    1. JACC Cardiovasc Interv. 2019 Jul 22;12(14):1369-1378 - PubMed
    1. Clin Res Cardiol. 2017 May;106(5):350-358 - PubMed
    1. JACC Cardiovasc Interv. 2017 May 8;10(9):931-939 - PubMed

Publication types

LinkOut - more resources