Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Meta-Analysis
. 2019 Oct;26(5):600-612.
doi: 10.1177/1526602819872154. Epub 2019 Aug 28.

Mortality After Paclitaxel-Coated Device Use in Dialysis Access: A Systematic Review and Meta-Analysis

Affiliations
Meta-Analysis

Mortality After Paclitaxel-Coated Device Use in Dialysis Access: A Systematic Review and Meta-Analysis

Krystal Dinh et al. J Endovasc Ther. 2019 Oct.

Abstract

Purpose: To report the risk of all-cause mortality in patients who underwent dialysis access treatment using paclitaxel-coated devices compared with percutaneous transluminal angioplasty (PTA) with an uncoated balloon. Materials and Methods: A systematic review and meta-analysis of randomized controlled trials were performed to investigate the mortality outcomes associated with paclitaxel-coated devices in the treatment of patients with a failing dialysis access (last search date February 28, 2019). The primary endpoint was all-cause mortality. This analysis included 8 studies comparing paclitaxel-coated balloon (PCB) angioplasty (n=327) and PTA (n=331) in the treatment of failing dialysis access. None investigated paclitaxel-coated stents. Mortality data were pooled using a random effects model. Statistical heterogeneity was evaluated with a chi-square test and the I2 statistic. Summary statistics are expressed as relative risk ratios (RR) with a 95% confidence interval (CI). Results: At the pooled mean follow-up of 13.5 months (median 12, range 6-24) all-cause mortality was similar in the PCB group (13.8%) compared with PTA (11.2%; RR 1.26, 95% CI 0.85 to 1.89, p=0.25; I2=0%). Subgroup analysis, stratified according to length of follow-up, confirmed that there were no statistically significant differences in mortality at short- and midterm follow-up [6-month (8 studies): 5.2% vs 4.8%, RR 1.24, 95% CI 0.62 to 2.47, p=0.55; 12-month (6 studies): 6.3% vs 6.0%, RR 1.06, 95% CI 0.43 to 2.63, p=0.90; and 24-month (3 studies): 19.0% vs 13.5%, RR 1.38, 95% CI 0.90 to 2.12, p=0.14). Conclusion: The analysis found no difference in short- to midterm mortality among patients treated with a drug-coated balloon compared with PTA. With proven benefit and no evidence of harm, the authors recommend ongoing use of PCB for the failing dialysis access.

Keywords: arteriovenous fistula; arteriovenous graft; balloon angioplasty; drug-coated balloon; drug-eluting stents; failing dialysis access; hemodialysis; mortality; paclitaxel; stenosis.

PubMed Disclaimer

MeSH terms

LinkOut - more resources