Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Review
. 2019 Aug 13:13:825.
doi: 10.3389/fnins.2019.00825. eCollection 2019.

Resting State fMRI: Going Through the Motions

Affiliations
Review

Resting State fMRI: Going Through the Motions

Sanam Maknojia et al. Front Neurosci. .

Abstract

Resting state functional magnetic resonance imaging (rs-fMRI) has become an indispensable tool in neuroscience research. Despite this, rs-fMRI signals are easily contaminated by artifacts arising from movement of the head during data collection. The artifacts can be problematic even for motions on the millimeter scale, with complex spatiotemporal properties that can lead to substantial errors in functional connectivity estimates. Effective correction methods must be employed, therefore, to distinguish true functional networks from motion-related noise. Research over the last three decades has produced numerous correction methods, many of which must be applied in combination to achieve satisfactory data quality. Subject instruction, training, and mild restraints are helpful at the outset, but usually insufficient. Improvements come from applying multiple motion correction algorithms retrospectively after rs-fMRI data are collected, although residual artifacts can still remain in cases of elevated motion, which are especially prevalent in patient populations. Although not commonly adopted at present, "real-time" correction methods are emerging that can be combined with retrospective methods and that promise better correction and increased rs-fMRI signal sensitivity. While the search for the ideal motion correction protocol continues, rs-fMRI research will benefit from good disclosure practices, such as: (1) reporting motion-related quality control metrics to provide better comparison between studies; and (2) including motion covariates in group-level analyses to limit the extent of motion-related confounds when studying group differences.

Keywords: image processing; motion artifacts; motion compensation; noise; resting state fMRI.

PubMed Disclaimer

References

    1. Aksoy M., Forman C., Straka M., Çukur T., Hornegger J., Bammer R., et al. (2012). Hybrid prospective and retrospective head motion correction to mitigate cross-calibration errors. Magn. Reson. Med. 67 1237–1251. 10.1002/mrm.23101 - DOI - PMC - PubMed
    1. Andersson J. L. R., Hutton C., Ashburner J., Turner R., Friston K. (2001). Modeling geometric deformations in EPI time series. Neuroimage 13 903–919. 10.1006/nimg.2001.0746 - DOI - PubMed
    1. Andrews-Hanna J. R., Snyder A. Z., Vincent J. L., Lustig C., Head D., Raichle M. E. E., et al. (2007). Disruption of large-scale brain systems in advanced aging. Neuron 56 924–935. 10.1016/J.NEURON.2007.10.038 - DOI - PMC - PubMed
    1. Anticevic A., Dierker D. L., Gillespie S. K., Repovs G., Csernansky J. G., Van Essen D. C., et al. (2008). Comparing surface-based and volume-based analyses of functional neuroimaging data in patients with schizophrenia. Neuroimage 41 835–848. 10.1016/j.neuroimage.2008.02.052 - DOI - PMC - PubMed
    1. Aranovitch A., Haeberlin M., Gross S., Dietrich B. E., Wilm B. J., Brunner D. O., et al. (2018). Prospective motion correction with NMR markers using only native sequence elements. Magn. Reson. Med. 79 2046–2056. 10.1002/mrm.26877 - DOI - PubMed

LinkOut - more resources