SPICED-ACS: Study of the potential impact of a computer-generated ECG diagnostic algorithmic certainty index in STEMI diagnosis: Towards transparent AI
- PMID: 31472927
- DOI: 10.1016/j.jelectrocard.2019.08.006
SPICED-ACS: Study of the potential impact of a computer-generated ECG diagnostic algorithmic certainty index in STEMI diagnosis: Towards transparent AI
Abstract
Background: Computerised electrocardiogram (ECG) interpretation diagnostic algorithms have been developed to guide clinical decisions like with ST segment elevation myocardial infarction (STEMI) where time in decision making is critical. These computer-generated diagnoses have been proven to strongly influence the final ECG diagnosis by the clinician; often called automation bias. However, the computerised diagnosis may be inaccurate and could result in a wrong or delayed treatment harm to the patient. We hypothesise that an algorithmic certainty index alongside a computer-generated diagnosis might mitigate automation bias. The impact of reporting a certainty index on the final diagnosis is not known.
Purpose: To ascertain whether knowledge of the computer-generated ECG algorithmic certainty index influences operator diagnostic accuracy.
Methodology: Clinicians who regularly analyse ECGs such as cardiology or acute care doctors, cardiac nurses and ambulance staff were invited to complete an online anonymous survey between March and April 2019. The survey had 36 ECGs with a clinical vignette of a typical chest pain and which were either a STEMI, normal, or borderline (but do not fit the STEMI criteria) along with an artificially created certainty index that was either high, medium, low or none. Participants were asked whether the ECG showed a STEMI and their confidence in the diagnosis. The primary outcomes were whether a computer-generated certainty index influenced interpreter's diagnostic decisions and improved their diagnostic accuracy. Secondary outcomes were influence of certainty index between different types of clinicians and influence of certainty index on user's own-diagnostic confidence.
Results: A total of 91 participants undertook the survey and submitted 3262 ECG interpretations of which 75% of ECG interpretations were correct. Presence of a certainty index significantly increased the odds ratio of a correct ECG interpretation (OR 1.063, 95% CI 1.022-1.106, p = 0.004) but there was no significant difference between correct certainty index and incorrect certainty index (OR 1.028, 95% CI 0.923-1.145, p = 0.615). There was a trend for low certainty index to increase odds ratio compared to no certainty index (OR 1.153, 95% CI 0.898-1.482, p = 0.264) but a high certainty index significantly decreased the odds ratio of a correct ECG interpretation (OR 0.492, 95% CI 0.391-0.619, p < 0.001). There was no impact of presence of a certainty index (p = 0.528) or correct certainty index (p = 0.812) on interpreters' confidence in their ECG interpretation.
Conclusions: Our results show that the presence of an ECG certainty index improves the users ECG interpretation accuracy. This effect is not seen with differing levels of confidence within a certainty index, with reduced ECG interpretation success with a high certainty index compared with a trend for increased success with a low certainty index. This suggests that a certainty index improves interpretation when there is an increased element of doubt, possibly forcing the ECG user to spend more time and effort analysing the ECG. Further research is needed looking at time spent analysing differing certainty indices with alternate ECG diagnoses.
Keywords: Algorithm; Automated decision-making; Automation bias; Electrocardiogram; Ischaemic heart disease; Myocardial infarction.
Crown Copyright © 2019. Published by Elsevier Inc. All rights reserved.
Similar articles
-
Emergency physician accuracy in interpreting electrocardiograms with potential ST-segment elevation myocardial infarction: Is it enough?Acute Card Care. 2016 Mar;18(1):7-10. doi: 10.1080/17482941.2016.1234058. Epub 2016 Oct 19. Acute Card Care. 2016. PMID: 27759433
-
The Recognition of STEMI by Paramedics and the Effect of Computer inTerpretation (RESPECT): a randomised crossover feasibility study.Emerg Med J. 2016 Jul;33(7):471-6. doi: 10.1136/emermed-2015-204988. Epub 2016 Feb 10. Emerg Med J. 2016. PMID: 26864325 Clinical Trial.
-
A Novel Algorithm for Improving the Diagnostic Accuracy of Prehospital ST-Elevation Myocardial Infarction.Prehosp Disaster Med. 2019 Oct;34(5):489-496. doi: 10.1017/S1049023X19004849. Epub 2019 Sep 11. Prehosp Disaster Med. 2019. PMID: 31507262
-
Context-independent identification of myocardial ischemia in the prehospital ECG of chest pain patients.J Electrocardiol. 2024 Jan-Feb;82:34-41. doi: 10.1016/j.jelectrocard.2023.10.009. Epub 2023 Nov 7. J Electrocardiol. 2024. PMID: 38006762 Review.
-
Artificial intelligence-enhanced electrocardiography for accurate diagnosis and management of cardiovascular diseases.J Electrocardiol. 2024 Mar-Apr;83:30-40. doi: 10.1016/j.jelectrocard.2024.01.006. Epub 2024 Jan 28. J Electrocardiol. 2024. PMID: 38301492 Review.
Cited by
-
ECG Monitoring Systems: Review, Architecture, Processes, and Key Challenges.Sensors (Basel). 2020 Mar 24;20(6):1796. doi: 10.3390/s20061796. Sensors (Basel). 2020. PMID: 32213969 Free PMC article. Review.
-
Demographics and Characteristics of Patients Admitted With Acute Coronary Syndrome to the Coronary Care Unit at King Abdulaziz University.Cureus. 2022 Jun 20;14(6):e26113. doi: 10.7759/cureus.26113. eCollection 2022 Jun. Cureus. 2022. PMID: 35875268 Free PMC article.
-
Artificial intelligence suppression as a strategy to mitigate artificial intelligence automation bias.J Am Med Inform Assoc. 2023 Sep 25;30(10):1684-1692. doi: 10.1093/jamia/ocad118. J Am Med Inform Assoc. 2023. PMID: 37561535 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Miscellaneous