Abstract
Wearable Electrocardiography (ECG) sensing textiles have been widely used due to their high flexibility, comfort, reusability and the possibility to be used for home-based and real-time measurements. Textile electrodes are dry and non-adhesive, therefor unlike conventional gel electrodes, they don't cause skin irritation and are more user-friendly especially for long-term and continuous monitoring outside the hospital. However, the challenge with textile electrodes is that the quality and reliability of recorded ECG signals by smart garments are more sensitive to different factors such as electrode placement, skin humidity, user activities and contact pressure. This review will particularly focus on the research findings regarding the influence of electrode placement on the quality of biosignal sensing, and will introduce the methods used by researchers to measure the optimal positions of the electrodes in wearable ECG garments. The review will help the designers to take into account different parameters, which affect the data quality, reliability and comfort, when selecting the electrode placement in a wearable ECG garment.
Copyright © 2019 Elsevier Inc. All rights reserved.
Similar articles
-
Wearable Smart Textiles for Long-Term Electrocardiography Monitoring-A Review.Sensors (Basel). 2021 Jun 17;21(12):4174. doi: 10.3390/s21124174. Sensors (Basel). 2021. PMID: 34204577 Free PMC article. Review.
-
Intelligent Medical Garments with Graphene-Functionalized Smart-Cloth ECG Sensors.Sensors (Basel). 2017 Apr 16;17(4):875. doi: 10.3390/s17040875. Sensors (Basel). 2017. PMID: 28420158 Free PMC article.
-
Design of a smart ECG garment based on conductive textile electrode and flexible printed circuit board.Technol Health Care. 2017 Aug 9;25(4):815-821. doi: 10.3233/THC-170828. Technol Health Care. 2017. PMID: 28436408
-
Evaluation of dry textile electrodes for long-term electrocardiographic monitoring.Biomed Eng Online. 2021 Jul 12;20(1):68. doi: 10.1186/s12938-021-00905-4. Biomed Eng Online. 2021. PMID: 34247646 Free PMC article.
-
Smart Textiles and Sensorized Garments for Physiological Monitoring: A Review of Available Solutions and Techniques.Sensors (Basel). 2021 Jan 26;21(3):814. doi: 10.3390/s21030814. Sensors (Basel). 2021. PMID: 33530403 Free PMC article. Review.
Cited by
-
Wearable Systems for Unveiling Collective Intelligence in Clinical Settings.Sensors (Basel). 2023 Dec 12;23(24):9777. doi: 10.3390/s23249777. Sensors (Basel). 2023. PMID: 38139623 Free PMC article. Review.
-
ECG Patient Simulator Based on Mathematical Models.Sensors (Basel). 2022 Jul 30;22(15):5714. doi: 10.3390/s22155714. Sensors (Basel). 2022. PMID: 35957270 Free PMC article.
-
Leveraging Emerging Technologies to Expand Accessibility and Improve Precision in Rehabilitation and Exercise for People with Disabilities.Int J Environ Res Public Health. 2024 Jan 10;21(1):79. doi: 10.3390/ijerph21010079. Int J Environ Res Public Health. 2024. PMID: 38248542 Free PMC article. Review.
-
The Role of Electrocardiography in Occupational Medicine, from Einthoven's Invention to the Digital Era of Wearable Devices.Int J Environ Res Public Health. 2020 Jul 10;17(14):4975. doi: 10.3390/ijerph17144975. Int J Environ Res Public Health. 2020. PMID: 32664277 Free PMC article. Review.
-
Dry Electrodes for Human Bioelectrical Signal Monitoring.Sensors (Basel). 2020 Jun 29;20(13):3651. doi: 10.3390/s20133651. Sensors (Basel). 2020. PMID: 32610658 Free PMC article. Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources