. 2020 Feb;83(2):749-764.
doi: 10.1002/mrm.27929. Epub 2019 Sep 4.

A 32-channel multi-coil setup optimized for human brain shimming at 9.4T

Affiliations
Free article

A 32-channel multi-coil setup optimized for human brain shimming at 9.4T

Ali Aghaeifar et al. Magn Reson Med. 2020 Feb.
Free article

Abstract

Purpose: A multi-coil shim setup is designed and optimized for human brain shimming. Here, the size and position of a set of square coils are optimized to improve the shim performance without increasing the number of local coils. Utilizing such a setup is especially beneficial at ultrahigh fields where B0 inhomogeneity in the human brain is more severe.

Methods: The optimization started with a symmetric arrangement of 32 independent coils. Three parameters per coil were optimized in parallel, including angular and axial positions on a cylinder surface and size of the coil, which were constrained by cylinder size, construction consideration, and amplifiers specifications. B0 maps were acquired at 9.4T in 8 healthy volunteers for use as training data. The global and dynamic shimming performance of the optimized multi-coil were compared in simulations and measurements to a symmetric design and to the scanner's second-order shim setup, respectively.

Results: The optimized multi-coil performs better by 14.7% based on standard deviation (SD) improvement with constrained global shimming in comparison to the symmetric positioning of the coils. Global shimming performance was comparable with a symmetric 65-channel multi-coil and full fifth-order spherical harmonic shim coils. On average, an SD of 48.4 and 31.9 Hz was achieved for in vivo measurements after global and dynamic slice-wise shimming, respectively.

Conclusions: An optimized multi-coil shim setup was designed and constructed for human whole-brain shimming. Similar performance of the multi-coils with many channels can be achieved with a fewer number of channels when the coils are optimally arranged around the target.

Keywords: B0 inhomogeneity; B0 shimming; echo planar imaging; multi-coil; optimization; ultrahigh field.

PubMed Disclaimer

References

REFERENCES

    1. Uğurbil K. Imaging at ultrahigh magnetic fields: history, challenges, and solutions. NeuroImage. 2018;168:7-32.
    1. Fiedler TM, Ladd ME, Bitz AK. SAR simulations & safety. NeuroImage. 2018;168:33-58.
    1. Stockmann JP, Wald LL. In vivo B0 field shimming methods for MRI at 7 T. NeuroImage. 2018;168:71-87.
    1. O'Donnell M, Edelstein WA. NMR imaging in the presence of magnetic field inhomogeneities and gradient field nonlinearities. Med Phys. 1985;12:20-26.
    1. Jezzard P, Clare S. Sources of distortion in functional MRI data. Hum Brain Mapp. 1999;8:80-85.

Publication types

LinkOut - more resources