MCP-based detectors: calibration and first photon radiation measurements
- PMID: 31490127
- DOI: 10.1107/S1600577519006295
MCP-based detectors: calibration and first photon radiation measurements
Abstract
Detectors based on microchannel plates (MCPs) are used to detect radiation from free-electron lasers. Three MCP detectors have been developed by JINR for the European XFEL (SASE1, SASE2 and SASE3 lines). These detectors are designed to operate in a wide dynamic range from the level of spontaneous emission to the SASE saturation level (between a few nJ up to 25 mJ), in a wide wavelength range from 0.05 nm to 0.4 nm for SASE1 and SASE2, and from 0.4 nm to 4.43 nm for SASE3. The detectors measure photon pulse energies with an anode and a photodiode. The photon beam image is observed with an MCP imager with a phosphor screen. At present, the SASE1 and SASE3 MCP detectors are commissioned with XFEL beams. Calibration and first measurements of photon radiation in multibunch mode are performed with the SASE1 and SASE3 MCPs. The MCP detector for SASE2 and its electronics are installed in the XFEL tunnel, technically commissioned, and are now ready for acceptance tests with the X-ray beam.
Keywords: XFEL physics; microchannel plate detectors; photon beam diagnostics.
Similar articles
-
X-ray photon diagnostics at the European XFEL.J Synchrotron Radiat. 2019 Sep 1;26(Pt 5):1422-1431. doi: 10.1107/S1600577519006611. Epub 2019 Aug 2. J Synchrotron Radiat. 2019. PMID: 31490130
-
Installation and commissioning of the European XFEL beam transport in the first two beamlines from a metrology point of view.Rev Sci Instrum. 2019 Feb;90(2):021701. doi: 10.1063/1.5055208. Rev Sci Instrum. 2019. PMID: 30831688
-
Characterization of nanoDot optically stimulated luminescence detectors and high-sensitivity MCP-N thermoluminescent detectors in the 40-300 kVp energy range.Med Phys. 2018 Jan;45(1):402-413. doi: 10.1002/mp.12691. Epub 2017 Dec 22. Med Phys. 2018. PMID: 29164632
-
X-ray imaging detectors for synchrotron and XFEL sources.IUCrJ. 2015 Apr 10;2(Pt 3):371-83. doi: 10.1107/S205225251500010X. eCollection 2015 May 1. IUCrJ. 2015. PMID: 25995846 Free PMC article. Review.
-
Overview of High-Performance Timing and Position-Sensitive MCP Detectors Utilizing Secondary Electron Emission for Mass Measurements of Exotic Nuclei at Nuclear Physics Facilities.Sensors (Basel). 2024 Nov 13;24(22):7261. doi: 10.3390/s24227261. Sensors (Basel). 2024. PMID: 39599038 Free PMC article. Review.
MeSH terms
LinkOut - more resources
Full Text Sources
Miscellaneous