Operation of photon diagnostic imagers for beam commissioning at the European XFEL
- PMID: 31490136
- DOI: 10.1107/S1600577519008737
Operation of photon diagnostic imagers for beam commissioning at the European XFEL
Abstract
X-ray photon beam diagnostic imagers are located at 24 positions in the European XFEL beam transport system to characterize the X-ray beam properties, and to give feedback for tuning and optimization of the electron acceleration and orbit, the undulators, and the X-ray optics. One year of commissioning allowed experience to be gained with these imagers, which will be reported here. The sensitive Spontaneous Radiation imager is useful for various investigations in spontaneous radiation mode: for undulator adjustments and for low-signal imaging applications. The high-resolution Free-Electron Laser imager, 10 µm spatial resolution, is extensively used for the monitoring of beam position, spot size and shape, gain curve measurements, and also for beam-intensity monitoring. The wide field-of-view pop-in monitors (up to 200 mm) are regularly used for alignment and tuning of the various X-ray optical components like mirrors, slits and monochromators, and also for on-line beam control of a stable beam position at the instruments. The Exit Slit imager after the soft X-ray monochromator provides spectral information of the beam together with multi-channel plate based single-pulse gating. For particular use cases, these special features of the imagers are described. Some radiation-induced degradation of scintillators took place in this initial commissioning phase, providing useful information for better understanding of damage thresholds. Visible-light radiation in the beam pipe generated by upstream bending magnets caused spurious reflections in the optical system of some of the imagers which can be suppressed by aluminium-coated scintillating screens.
Keywords: X-ray free-electron lasers; X-ray imaging; beam diagnostics; beam transport systems; scintillators.
Similar articles
-
X-ray photon diagnostics at the European XFEL.J Synchrotron Radiat. 2019 Sep 1;26(Pt 5):1422-1431. doi: 10.1107/S1600577519006611. Epub 2019 Aug 2. J Synchrotron Radiat. 2019. PMID: 31490130
-
A micro channel-cut crystal X-ray monochromator for a self-seeded hard X-ray free-electron laser.J Synchrotron Radiat. 2019 Sep 1;26(Pt 5):1496-1502. doi: 10.1107/S1600577519008841. Epub 2019 Aug 27. J Synchrotron Radiat. 2019. PMID: 31490137
-
MCP-based detectors: calibration and first photon radiation measurements.J Synchrotron Radiat. 2019 Sep 1;26(Pt 5):1400-1405. doi: 10.1107/S1600577519006295. Epub 2019 Jul 12. J Synchrotron Radiat. 2019. PMID: 31490127
-
X-ray free electron laser single-particle analysis for biological systems.Curr Opin Struct Biol. 2017 Apr;43:163-169. doi: 10.1016/j.sbi.2017.03.014. Epub 2017 May 10. Curr Opin Struct Biol. 2017. PMID: 28501339 Review.
-
Microscopy of biological sample through advanced diffractive optics from visible to X-ray wavelength regime.Microsc Res Tech. 2004 Nov;65(4-5):252-62. doi: 10.1002/jemt.20122. Microsc Res Tech. 2004. PMID: 15630683 Review.
Cited by
-
The soft X-ray monochromator at the SASE3 beamline of the European XFEL: from design to operation.J Synchrotron Radiat. 2022 Sep 1;29(Pt 5):1299-1308. doi: 10.1107/S1600577522007627. Epub 2022 Aug 23. J Synchrotron Radiat. 2022. PMID: 36073890 Free PMC article.
-
Development of MHz X-ray phase contrast imaging at the European XFEL.J Synchrotron Radiat. 2025 Jan 1;32(Pt 1):17-28. doi: 10.1107/S160057752400986X. Epub 2025 Jan 1. J Synchrotron Radiat. 2025. PMID: 39565194 Free PMC article.
-
Materials Imaging and Dynamics (MID) instrument at the European X-ray Free-Electron Laser Facility.J Synchrotron Radiat. 2021 Mar 1;28(Pt 2):637-649. doi: 10.1107/S1600577521001302. Epub 2021 Feb 15. J Synchrotron Radiat. 2021. PMID: 33650576 Free PMC article.
-
The High Energy Density Scientific Instrument at the European XFEL.J Synchrotron Radiat. 2021 Sep 1;28(Pt 5):1393-1416. doi: 10.1107/S1600577521007335. Epub 2021 Aug 23. J Synchrotron Radiat. 2021. PMID: 34475288 Free PMC article.
-
Diamond sensors for hard X-ray energy and position resolving measurements at the European XFEL.J Synchrotron Radiat. 2024 Sep 1;31(Pt 5):1029-1036. doi: 10.1107/S1600577524006015. Epub 2024 Jul 30. J Synchrotron Radiat. 2024. PMID: 39078693 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources