Long-T2 -suppressed zero echo time imaging with weighted echo subtraction and gradient error correction
- PMID: 31502718
- DOI: 10.1002/mrm.27925
Long-T2 -suppressed zero echo time imaging with weighted echo subtraction and gradient error correction
Abstract
Purpose: To perform direct, selective MRI of short-T2 tissues using zero echo time (ZTE) imaging with weighted echo subtraction (WSUB).
Methods: Radial imaging was performed at 7T, acquiring both ZTE and gradient echo (GRE) signals created by bipolar gradients. Long-T2 suppression was achieved by weighted subtraction of ZTE and GRE images. Special attention was given to imperfections of gradient dynamics, to which radial GRE imaging is particularly susceptible. To compensate for gradient errors, matching of gradient history was combined with data correction based on trajectory measurement. The proposed approach was first validated in phantom experiments and then demonstrated in musculoskeletal (MSK) imaging.
Results: Trajectory analysis and phantom imaging demonstrated that gradient imperfections were successfully addressed. Gradient history matching enabled consistency between antiparallel projections as required for deriving zeroth-order eddy current dynamics. Trajectory measurement provided individual echo times per projection that showed considerable variation between gradient directions. In in vivo imaging of knee, ankle, and tibia, the proposed approach enabled high-resolution 3D depiction of bone, tendons, and ligaments. Distinct contrast of these structures indicates excellent selectivity of long-T2 suppression. Clarity of depiction also confirmed sufficient SNR of short-T2 tissues, achieved by high baseline sensitivity at 7T combined with high SNR efficiency of ZTE acquisition.
Conclusion: Weighted subtraction of ZTE and GRE data reconciles robust long-T2 suppression with fastest k-space coverage and high SNR efficiency. This approach enables high-resolution imaging with excellent selectivity to short-T2 tissues, which are of major interest in MSK and neuroimaging applications.
Keywords: bone; eddy currents; ligaments; musculoskeletal imaging; short-T2 imaging; tendons.
© 2019 International Society for Magnetic Resonance in Medicine.
Similar articles
-
Ultrashort echo time and zero echo time MRI at 7T.MAGMA. 2016 Jun;29(3):359-70. doi: 10.1007/s10334-015-0509-0. Epub 2015 Dec 24. MAGMA. 2016. PMID: 26702940 Free PMC article.
-
Filling the dead-time gap in zero echo time MRI: Principles compared.Magn Reson Med. 2018 Apr;79(4):2036-2045. doi: 10.1002/mrm.26875. Epub 2017 Aug 30. Magn Reson Med. 2018. PMID: 28856717
-
Imaging and T2 relaxometry of short-T2 connective tissues in the knee using ultrashort echo-time double-echo steady-state (UTEDESS).Magn Reson Med. 2017 Dec;78(6):2136-2148. doi: 10.1002/mrm.26577. Epub 2017 Jan 11. Magn Reson Med. 2017. PMID: 28074498 Free PMC article.
-
Imaging of the musculoskeletal system in vivo using ultra-high field magnetic resonance at 7 T.Invest Radiol. 2009 Sep;44(9):613-8. doi: 10.1097/RLI.0b013e3181b4c055. Invest Radiol. 2009. PMID: 19652609 Review.
-
Clinical application of ultrashort echo time (UTE) and zero echo time (ZTE) magnetic resonance (MR) imaging in the evaluation of osteoarthritis.Skeletal Radiol. 2023 Nov;52(11):2149-2157. doi: 10.1007/s00256-022-04269-1. Epub 2023 Jan 6. Skeletal Radiol. 2023. PMID: 36607355 Free PMC article. Review.
Cited by
-
Ultrashort-T2* mapping at 7 tesla using an optimized pointwise encoding time reduction with radial acquisition (PETRA) sequence at standard and extended echo times.PLoS One. 2025 Apr 17;20(4):e0310590. doi: 10.1371/journal.pone.0310590. eCollection 2025. PLoS One. 2025. PMID: 40245029 Free PMC article.
-
An Update in Qualitative Imaging of Bone Using Ultrashort Echo Time Magnetic Resonance.Front Endocrinol (Lausanne). 2020 Sep 29;11:555756. doi: 10.3389/fendo.2020.555756. eCollection 2020. Front Endocrinol (Lausanne). 2020. PMID: 33117275 Free PMC article. Review.
-
Inversion recovery zero echo time (IR-ZTE) imaging for direct myelin detection in human brain: a feasibility study.Quant Imaging Med Surg. 2020 May;10(5):895-906. doi: 10.21037/qims.2020.04.13. Quant Imaging Med Surg. 2020. PMID: 32489915 Free PMC article.
-
Zero-TE MRI: principles and applications in the head and neck.Br J Radiol. 2022 Aug 1;95(1136):20220059. doi: 10.1259/bjr.20220059. Epub 2022 Jun 10. Br J Radiol. 2022. PMID: 35616709 Free PMC article. Review.
-
Quantitative Ultrashort Echo Time (UTE) Magnetic Resonance Imaging of Bone: An Update.Front Endocrinol (Lausanne). 2020 Sep 18;11:567417. doi: 10.3389/fendo.2020.567417. eCollection 2020. Front Endocrinol (Lausanne). 2020. PMID: 33071975 Free PMC article. Review.
References
REFERENCES
-
- Rad HS, Lam SCB, Magland JF, et al. Quantifying cortical bone water in vivo by three-dimensional ultra-short echo-time MRI. NMR Biomed. 2011;24:855-864.
-
- Gatehouse PD, Bydder GM. Magnetic resonance imaging of short T2 components in tissue. Clin Radiol. 2003;58:1-19.
-
- Gold GE, Pauly JM, Macovski A, Herfkens RJ. MR spectroscopic imaging of collagen: tendons and knee menisci. Magn Reson Med. 1995;34:647-654.
-
- Wilhelm MJ, Ong HH, Wehrli SL, et al. Direct magnetic resonance detection of myelin and prospects for quantitative imaging of myelin density. Proc Natl Acad Sci U S A. 2012;109:9605-9610.
-
- Granke M, Does MD, Nyman JS. The role of water compartments in the material properties of cortical bone. Calcif Tissue Int. 2015;97:292-307.
MeSH terms
LinkOut - more resources
Full Text Sources
Medical