Comparison of simultaneous plasma clearance of 99mTc-DTPA and 51Cr-EDTA: can one tracer replace the other?
- PMID: 31502901
- DOI: 10.1080/00365513.2019.1658217
Comparison of simultaneous plasma clearance of 99mTc-DTPA and 51Cr-EDTA: can one tracer replace the other?
Abstract
Both 99mTc-DTPA and 51Cr-EDTA are widely used to determine glomerular filtration rate (GFR), but few direct comparative studies exist. The shortage of 51Cr-EDTA makes a direct comparison highly relevant. The aim of the study was to investigate if there is any clinically relevant difference between plasma clearance of 99mTc-DTPA and 51Cr-EDTA. Patients ≥18 years of age referred for routine GFR measurement by 51Cr-EDTA were prospectively enrolled. The two tracers (10 MBq 99mTc-DTPA (CaNa3-DTPA) and 2.5 MBq 51Cr-EDTA) were intravenously injected at time zero. A standard 4-sample technique was applied with samples collected at 180, 200, 220 and 240 min, if the estimated GFR (eGFR) was ≥30 mL/min. A comparison of single-sample GFR based on the 200 min sample was also conducted. Fifty-six patients were enrolled in the study. All patients had an estimated GFR >30 mL/min/1.73 m2. No patients suffered from ascites or significant oedema. The mean 51Cr-EDTA plasma clearance was 82 mL/min (range 16-226). The plasma clearances determined by the two methods were highly correlated (r = 0.993). The plasma clearance was significantly higher when measured by 99mTc-DTPA than by 51Cr-EDTA (p = 0.01), but the numerical difference was minimal (mean difference 1.4 mL/min; 95% limits of agreement (LOA) -6.6 to 9.4). The difference between the two methods was independent of the level of renal function. Similar results were found for one-sample GFR. No clinically relevant differences were found between the plasma clearance of 99mTc-DTPA and that of 51Cr-EDTA. Therefore, 99mTc-DTPA can replace 51Cr-EDTA when needed.
Keywords: 51Cr-EDTA; 99mTcDTPA; GFR; glomerular filtration rate; plasma clearance; renal function.
Similar articles
-
Glomerular filtration rate: comparison of simultaneous plasma clearance of 99mTc-DTPA and 51Cr-EDTA revisited.Scand J Clin Lab Invest. 2020 Sep;80(5):408-411. doi: 10.1080/00365513.2020.1759138. Epub 2020 May 2. Scand J Clin Lab Invest. 2020. PMID: 32362172
-
Estimating GFR in children with 99mTc-DTPA renography: a comparison with single-sample 51Cr-EDTA clearance.Clin Physiol Funct Imaging. 2010 May;30(3):169-74. doi: 10.1111/j.1475-097X.2009.00910.x. Epub 2010 Feb 27. Clin Physiol Funct Imaging. 2010. PMID: 20214666
-
Comparison of 99mTc-DTPA and 51Cr-EDTA for glomerular filtration rate measurement with the continuous infusion method.J Nephrol. 2023 Dec;36(9):2457-2465. doi: 10.1007/s40620-023-01612-0. Epub 2023 Apr 24. J Nephrol. 2023. PMID: 37093492
-
Measurement of Glomerular Filtration Rate.Semin Nucl Med. 2022 Jul;52(4):453-466. doi: 10.1053/j.semnuclmed.2021.12.005. Epub 2022 Jan 19. Semin Nucl Med. 2022. PMID: 35063168 Review.
-
The clearance concept with special reference to determination of glomerular filtration rate in patients with fluid retention.Clin Physiol Funct Imaging. 2015 Jan;35(1):7-16. doi: 10.1111/cpf.12149. Epub 2014 Apr 20. Clin Physiol Funct Imaging. 2015. PMID: 24750696 Review.
Cited by
-
Effect of Spironolactone on Kidney Function in Kidney Transplant Recipients (the SPIREN trial): A Randomized Placebo-Controlled Clinical Trial.Clin J Am Soc Nephrol. 2024 Jun 1;19(6):755-766. doi: 10.2215/CJN.0000000000000439. Epub 2024 Feb 27. Clin J Am Soc Nephrol. 2024. PMID: 38416033 Free PMC article. Clinical Trial.
-
Comparison of 51Cr-EDTA and 99mTc-DTPA for glomerular filtration rate measurement.J Nephrol. 2021 Jun;34(3):729-737. doi: 10.1007/s40620-020-00932-9. Epub 2021 Mar 4. J Nephrol. 2021. PMID: 33661505
-
Measured GFR in murine animal models: review on methods, techniques, and procedures.Pflugers Arch. 2023 Nov;475(11):1241-1250. doi: 10.1007/s00424-023-02841-9. Epub 2023 Aug 8. Pflugers Arch. 2023. PMID: 37552296 Free PMC article. Review.
-
Prospective validation of an equation based on plasma cystatin C for monitoring the glomerular filtration rate in children treated with cisplatin or ifosfamide for cancer.Cancer Chemother Pharmacol. 2024 Apr;93(4):393-395. doi: 10.1007/s00280-023-04597-6. Epub 2023 Oct 3. Cancer Chemother Pharmacol. 2024. PMID: 37789166
-
Individualized calibration of estimated glomerular filtration rate for serial renal function determination: a pilot study.Sci Rep. 2025 May 27;15(1):18523. doi: 10.1038/s41598-025-03561-z. Sci Rep. 2025. PMID: 40425768 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Research Materials
Miscellaneous