The Effect on Fit of Multiple Consecutive Donning and Doffing of N95 Filtering Facepiece Respirators
- PMID: 31504129
- DOI: 10.1093/annweh/wxz060
The Effect on Fit of Multiple Consecutive Donning and Doffing of N95 Filtering Facepiece Respirators
Abstract
Background: N95 filtering facepiece respirators (FFRs) are widely used in healthcare to reduce transmission of airborne infectious diseases. These respirators are generally described as single use or limited reuse devices, but cost and operational issues mean that they may be donned and doffed multiple times. There is scant research on the effect of this practice on adequacy of fit.
Objective: The purpose of this study was to measure the effect on respirator fit of multiple donning and doffing of N95 FFRs.
Methods: This was an experiment in which 16 women and 9 men employed by the National Institute for Occupational Health (NIOH), Johannesburg, donned their same N95 FFR six times. All 25 were trained in the correct wearing of the devices before the experiment. Four models of respirators were used: the six who did not use respirators at work (novice subjects) were issued a 3M 1860 FFR and the others used their currently supplied one. During the experiment subjects donned their respirators under the supervision of the tester. Quantitative fit testing was done in the NIOH Occupational Hygiene laboratory after each donning according to the OSHA-Accepted Fit Test Protocol using the TSI PortaCount Pro+ Model 8038 Respirator Fit Tester. During the test, fit was measured after each of seven exercises and then an overall fit factor was computed. Only individuals who achieved an initial overall fit factor of ≥100 were allowed to continue participation in the study. Median overall fit factors were calculated for the 25 subjects for each donning and changes across them was examined using Wilcoxon rank sum tests. Men and women and frequent and infrequent users were compared across the six tests. Infrequent use was defined as subjects who wore respirators ≤ once per week, and novice subjects.
Results: Two subjects (8%) had an overall fit factor <100 at fit Test 2, 6 (24%) at Test 3, and 8 (32%) at Tests 4, 5, and 6. Thirteen respirator users (52%) achieved ≥100 throughout the fit testing, so 12 had at least one failure at either Tests 2-6. Five of the 12 subjects with at least one failure showed persistent failures on all subsequent donnings. Six subjects out of 12 (50%) who failed a fit test achieved an overall fit factor >100 at a subsequent test. There was a significant difference between the median first and sixth overall fit factors (195 versus 150; P = 0.0271), but not between the second and sixth (161 versus 150; P = 0.3584). Men and women had similar overall fit factors, but infrequent users had larger average overall fit factors than frequent users after all six donnings.
Conclusion: Forty-eight percent of study subjects failed at least one fit test after re-donning an N95 FFR. The fit test data suggest that donning practices probably accounted for the fit test failures. The 50% of subjects who produced overall fit factors ≥100 after a test of <100 supports this contention.
Keywords: filtering facepiece respirator; overall fit factor; respirator fit; respirator re-donning.
© The Author(s) 2019. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.
Similar articles
-
Impact of multiple consecutive donnings on filtering facepiece respirator fit.Am J Infect Control. 2012 May;40(4):375-80. doi: 10.1016/j.ajic.2011.05.003. Epub 2011 Aug 23. Am J Infect Control. 2012. PMID: 21864945
-
Impact of three biological decontamination methods on filtering facepiece respirator fit, odor, comfort, and donning ease.J Occup Environ Hyg. 2011 Jul;8(7):426-36. doi: 10.1080/15459624.2011.585927. J Occup Environ Hyg. 2011. PMID: 21732856
-
Fitting characteristics of eighteen N95 filtering-facepiece respirators.J Occup Environ Hyg. 2004 Apr;1(4):262-71. doi: 10.1080/15459620490433799. J Occup Environ Hyg. 2004. PMID: 15204866
-
Decontamination Strategies for Filtering Facepiece Respirators (FFRs) in Healthcare Organizations: A Comprehensive Review.Ann Work Expo Health. 2021 Jan 14;65(1):26-52. doi: 10.1093/annweh/wxaa090. Ann Work Expo Health. 2021. PMID: 32929450 Review.
-
Efficacy and safety of disinfectants for decontamination of N95 and SN95 filtering facepiece respirators: a systematic review.J Hosp Infect. 2020 Nov;106(3):504-521. doi: 10.1016/j.jhin.2020.08.005. Epub 2020 Aug 13. J Hosp Infect. 2020. PMID: 32800824 Free PMC article.
Cited by
-
Failure Rates During Reuse of Disposable N95 Masks in Clinical Practice in the Emergency Department.West J Emerg Med. 2021 Apr 19;22(3):547-551. doi: 10.5811/westjem.2021.1.49960. West J Emerg Med. 2021. PMID: 34125025 Free PMC article.
-
Correlation Between N95 Extended Use and Reuse and Fit Failure in an Emergency Department.JAMA. 2020 Jul 7;324(1):94-96. doi: 10.1001/jama.2020.9843. JAMA. 2020. PMID: 32496504 Free PMC article.
-
Mask shortage during epidemics and pandemics: a scoping review of interventions to overcome limited supply.BMJ Open. 2020 Nov 27;10(11):e040547. doi: 10.1136/bmjopen-2020-040547. BMJ Open. 2020. PMID: 33247019 Free PMC article.
-
Quantifying the Health Benefits of Face Masks and Respirators to Mitigate Exposure to Severe Air Pollution.Geohealth. 2021 Sep 1;5(9):e2021GH000482. doi: 10.1029/2021GH000482. eCollection 2021 Sep. Geohealth. 2021. PMID: 34541439 Free PMC article.
-
Reuse of N95/PFF2 masks in clinical practice: morphological and structural analysis.Rev Lat Am Enfermagem. 2024 Jul 5;32:e4209. doi: 10.1590/1518-8345.7045.4209. eCollection 2024. Rev Lat Am Enfermagem. 2024. PMID: 38985043 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Medical