Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2021 Jul;34(14):2340-2348.
doi: 10.1080/14767058.2019.1666818. Epub 2019 Sep 18.

Assessment of the angle of progression and distance perineum-head in the prediction of type of delivery and duration of labor using intrapartum ultrasonography

Affiliations

Assessment of the angle of progression and distance perineum-head in the prediction of type of delivery and duration of labor using intrapartum ultrasonography

Raimundo Homero Carvalho Neto et al. J Matern Fetal Neonatal Med. 2021 Jul.

Abstract

Objective: To evaluate the relevance of the angle of progression (AOP) and head-perineum distance (HPD) for predicting the type of delivery and duration of the second stage of labor using intrapartum ultrasonography.

Methods: In total, 221 women in labor with a single gestational sac at ≥37 weeks of gestation and fetuses in cephalic presentation underwent two-dimensional ultrasonography by transperineal route for measurements of AOP and HPD. Correlations between the type of delivery (vaginal or surgical (cesarean section and forceps)), duration of the second stage of labor, and fetal and maternal characteristics were assessed. AOP and HPD variables were separately studied in the first and second stages of labor. Multivariate logistic regression was followed in stages to identify the predictors for the surgical delivery outcome - stepwise forward method.

Results: In total, 153 (69.2%) women underwent vaginal deliveries, 7 (3.2%) underwent forceps deliveries, and 61 (27.6%) underwent cesarean deliveries. AOP was a statistically significant parameter in first and second stages of labor (107.8 ± 12.1° versus 100.8 ± 13.7°; p = .017), with an inverse correlation with the occurrence of vaginal delivery. HPD was a statistically significant parameter in the second stage of labor (3.42 ± 0.84 cm versus 4.17 ± 0.54 cm; p < .003), with a direct correlation with the occurrence of surgical delivery. The value of AOP that optimized the curve was 129.9° with 85% specificity and 63% sensitivity for the vaginal delivery endpoint. The value of HPD that optimized the curve was 4.3 cm with 69% specificity and 89% sensitivity for the surgical delivery endpoint. In the first phase, the variables defining the type of delivery were the following: height, body mass index, and AOP. In the second phase, the variables defining were the following: height, labor analgesia, HPD, and position of the fetal occiput.

Conclusion: AOP and HPD determined by intrapartum ultrasonography were associated with duration of labor, which may aid in predicting the type of delivery in association with clinical parameters.

Keywords: Cesarean section; labor; prediction; ultrasonography; vaginal delivery.

PubMed Disclaimer

Similar articles

Cited by

LinkOut - more resources