. 2019 Nov;45(11):757-762.
doi: 10.1016/j.jcjq.2019.07.001. Epub 2019 Sep 13.

Automating Vancomycin Monitoring to Improve Patient Safety

Automating Vancomycin Monitoring to Improve Patient Safety

Vimal Mishra et al. Jt Comm J Qual Patient Saf. 2019 Nov.

Abstract

Introduction: Intravenous vancomycin is a frequently used antibiotic and a common cause of medication-related harm because of its narrow therapeutic range. Improving monitoring of drug levels with automation in the electronic health record (EHR) may decrease this harm.

Methods: After examining the existing state of vancomycin ordering, administration, and monitoring, an automated process was created in the EHR that, on initiation of a new vancomycin order, automatically ordered a vancomycin trough level 30 minutes before the fourth dose. In addition, a nursing alert was integrated into the bar coding medication administration process that, if no trough level had been drawn by the time of the administration of the fourth dose, prompted the nurse to draw a trough level. Data from a three-month, post-implementation period was compared to data from a preceding three-month period.

Results: The frequency of trough levels drawn between the third and fourth dose increased from 58.6% to 75.8% (p < 0.01). However, the percentage of trough levels drawn within one hour of the fourth dose remained unchanged, possibly because nursing staff waited for the result of the level prior to administering the next dose of vancomycin. A minority of patients in both groups had trough levels that were in range (difference between groups, p = 0.46).

Conclusion: Automation of vancomycin monitoring was associated with improvement in the frequency of monitoring and only delayed medication dosing by six minutes. Because vancomycin is high risk, this type of process should be broadly implemented, and outcomes should be assessed to identify unexpected outcomes and necessary further refinements.