Review
. 2019;10(4):232-238.
doi: 10.5847/wjem.j.1920-8642.2019.04.007.

The utility of point-of-care ultrasound in the assessment of volume status in acute and critically ill patients

Affiliations
Review

The utility of point-of-care ultrasound in the assessment of volume status in acute and critically ill patients

Ali Pourmand et al. World J Emerg Med. 2019.

Abstract

Background: Volume resuscitation has only been demonstrated to be effective in approximately fifty percent of patients. The remaining patients do not respond to volume resuscitation and may even develop adverse outcomes (such as acute pulmonary edema necessitating endotracheal intubation). We believe that point-of-care ultrasound is an excellent modality by which to adequately predict which patients may benefit from volume resuscitation.

Data resources: We performed a search using PubMed, Scopus, and MEDLINE. The following search terms were used: fluid responsiveness, ultrasound, non-invasive, hemodynamic, fluid challenge, and passive leg raise. Preference was given to clinical trials and review articles that were most relevant to the topic of assessing a patient's cardiovascular ability to respond to intravenous fluid administration using ultrasound.

Results: Point-of-care ultrasound can be easily employed to measure the diameter and collapsibility of various large vessels including the inferior vena cava, common carotid artery, subclavian vein, internal jugular vein, and femoral vein. Such parameters are closely related to dynamic measures of fluid responsiveness and can be used by providers to help guide fluid resuscitation in critically ill patients.

Conclusion: Ultrasound in combination with passive leg raise is a non-invasive, cost- and time-effective modality that can be employed to assess volume status and response to fluid resuscitation. Traditionally sonographic studies have focused on the evaluation of large veins such as the inferior vena cava, and internal jugular vein. A number of recently published studies also demonstrate the usefulness of evaluating large arteries to predict volume status.

Keywords: Fluid responsiveness; Hemodynamic; Non-invasive; Stroke volume; Ultrasound.

PubMed Disclaimer

References

    1. Kelly N, Esteve R, Papadimos TJ, Sharpe RP, Keeney SA, DeQuevedo R, et al. Clinician-performed ultrasound in hemodynamic and cardiac assessment:a synopsis of current indications and limitations. Eur J Trauma Emerg Surg. 2015;41(5):469–80. - PubMed
    1. Karacabey S, Sanri E, Guneysel O. A non-invasive method for assessment of intravascular fluid status:Inferior vena cava diameters and collapsibility index. Pak J Med Sci. 2016;32(4):836–40. - PMC - PubMed
    1. Ansari BM, Zochios V, Falter F, Klein AA. Physiological controversies and methods used to determine fluid responsiveness:A qualitative systematic review. Anaesthesia. 2016;71(1):94–105. - PubMed
    1. Mandeville JC, Colebourn CL. Can transthoracic echocardiography be used to predict fluid responsiveness in the critically ill patient?A systematic review. Crit Care Res Pract 2012. 2012 513480. - PMC - PubMed
    1. Marik PE, Lemson J. Fluid responsiveness:An evolution of our understanding. Br J Anaesth. 2014;112(4):617–20. - PubMed

LinkOut - more resources