Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2019 Oct:77:101643.
doi: 10.1016/j.compmedimag.2019.101643. Epub 2019 Aug 14.

Fully automated method for glaucoma screening using robust optic nerve head detection and unsupervised segmentation based cup-to-disc ratio computation in retinal fundus images

Affiliations

Fully automated method for glaucoma screening using robust optic nerve head detection and unsupervised segmentation based cup-to-disc ratio computation in retinal fundus images

Amed Mvoulana et al. Comput Med Imaging Graph. 2019 Oct.

Abstract

Background and objective: Visual impairment affects a significant part of the population worldwide. Glaucoma is one of these main causes, a chronic eye disease leading to progressive vision loss. Early glaucoma screening is an important task, allowing a slowing down of the pathology spreading and avoidance of irreversible vision damages. When manual assessment by experts suffers from disadvantages, exploiting the relevant Cup-to-Disc Ratio (CDR) feature as a structural indicator to assess the damage to the optic nerve head (ONH) is an efficient way for early glaucoma screening and diagnosis.

Methods: In this paper, we propose a new fully automated methodology for glaucoma screening and diagnosis from retinal fundus images. In order to allow eye examination in remote locations with limited access to clinical facilities, we focus in this work on the development of a computationally-efficient algorithm for further implementation on mobile devices. First, the method provides a robust optic disc (OD) detection method, combining a brightness criterion and a template matching technique, to effectively detect the optic disc (OD) even in the presence of bright lesions associated to pathological cases. Second, an efficient optic cup (OC) and optic disc (OD) segmentation is performed, using a texture-based and model-based approach. Finally, Cup-to-Disc Ratio (CDR) computation leads to glaucoma screening with a classification between healthy and glaucomatous patients.

Results: The proposed approach for glaucoma screening and diagnosis have been tested on the publicly available DRISHTI-GS1 dataset. Fifty retinal images are provided and labeled healthy or glaucomatous by trained specialists. The method achieves 98% of accuracy on final glaucoma screening and diagnosis, and excellent performance rates on evaluation metrics, outperforming the state-of-the-art CDR feature-based approaches.

Conclusions: We proposed a fully automated method for glaucoma screening and diagnosis from retinal images. Excellent performance was obtained on final screening, classifying healthy and glaucomatous subjects. As it effectively detects the presence of glaucoma, in a low-computational manner, the approach can be part of a mobile help-diagnosis system, to improve the final diagnosis by the specialist and develop widespread visual health programs.

Keywords: Cup-to-disc ratio; Diagnosis; Glaucoma screening; Optic cup; Optic disc; Retinal images.

PubMed Disclaimer

Similar articles

Cited by