Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2019 Oct;70(4):1177-1191.e9.
doi: 10.1016/j.jvs.2019.02.030.

Total IN.PACT drug-coated balloon initiative reporting pooled imaging and propensity-matched cohorts

Affiliations
Free article

Total IN.PACT drug-coated balloon initiative reporting pooled imaging and propensity-matched cohorts

Mehdi H Shishehbor et al. J Vasc Surg. 2019 Oct.
Free article

Abstract

Objective: Randomized controlled trials have shown that drug-coated balloons (DCBs) provide superior results compared with percutaneous transluminal angioplasty (PTA) for the treatment of femoropopliteal artery disease. However, these trials have generally included short lesions, few occlusions, and small sample sizes. The present study was an individual-level pooled analysis of duplex ultrasonography (DUS) core laboratory-adjudicated and clinical events committee-adjudicated IN.PACT Admiral DCB subjects across two randomized controlled trials and two single-arm prospective studies to characterize the safety and effectiveness of DCB compared with PTA.

Methods: The subjects were treated with DCB (n = 926) or PTA (n = 143). The end points through 12 months included DUS core laboratory-adjudicated primary patency and clinically driven target lesion revascularization (CD-TLR) using Kaplan-Meier estimates and primary safety using proportions. A propensity-matched analysis of DCB (n = 466) to PTA (n = 136) was conducted to address confounders.

Results: At 12 months, DCB compared with PTA had significantly greater primary patency (88.8% vs 53.9%; P < .001), freedom from CD-TLR (94.3% vs 80.2%; P < .001), and better primary safety composite end point (94.1% vs 78.0%; P < .001). After propensity-matched analysis, DCB remained superior to PTA at 12 months for primary patency (90.5% vs 53.8%; P < .001), freedom from CD-TLR (96.9% vs 80.7%; P < .001), and the primary safety composite end point (96.3% vs 78.4%; P < .001). Across multiple prespecified subgroup analyses, including provisional stenting, DCB remained persistently superior to PTA.

Conclusions: In the largest, DUS core laboratory-adjudicated, multiethnic, pooled DCB series to date, the IN.PACT Admiral DCB demonstrated significantly greater primary patency, freedom from CD-TLR, and better composite safety at 12 months compared with PTA.

Trial registration: ClinicalTrials.gov NCT01175850 NCT01566461 NCT01947478 NCT02118532 NCT01609296.

Keywords: Drug-coated balloon; Duplex ultrasonography; Patency; Peripheral artery disease.

PubMed Disclaimer

Publication types

MeSH terms

Substances

Associated data