Randomized Controlled Trial
. 2019 Nov;50(11):3013-3020.
doi: 10.1161/STROKEAHA.118.024076. Epub 2019 Sep 24.

Stent Design, Restenosis and Recurrent Stroke After Carotid Artery Stenting in the International Carotid Stenting Study

Affiliations
Randomized Controlled Trial

Stent Design, Restenosis and Recurrent Stroke After Carotid Artery Stenting in the International Carotid Stenting Study

Mandy D Müller et al. Stroke. 2019 Nov.

Abstract

Background and Purpose- Open-cell carotid artery stents are associated with a higher peri-procedural stroke risk than closed-cell stents. However, the effect of stent design on long-term durability of carotid artery stenting (CAS) is unknown. We compared the medium- to long-term risk of restenosis and ipsilateral stroke between patients treated with open-cell stents versus closed-cell stents in the ICSS (International Carotid Stenting Study). Methods- Patients with symptomatic carotid stenosis were randomized to CAS or endarterectomy and followed with duplex ultrasound for a median of 4.0 years. We analyzed data from patients with completed CAS procedures, known stent design, and available ultrasound follow-up. The primary outcome, moderate or higher restenosis (≥50%) was defined as a peak systolic velocity of >1.3 m/s on ultrasound or occlusion of the treated internal carotid artery and analyzed with interval-censored models. Results- Eight hundred fifty-five patients were allocated to CAS. Seven hundred fourteen patients with completed CAS and known stent design were included in the current analysis. Of these, 352 were treated with open-cell and 362 with closed-cell stents. Moderate or higher restenosis occurred significantly less frequently in patients treated with open-cell (n=113) than closed-cell stents (n=154; 5-year risks were 35.5% versus 46.0%; unadjusted hazard ratio, 0.68; 95% CI, 0.53-0.88). There was no significant difference in the risk of severe restenosis (≥70%) after open-cell stenting (n=27) versus closed-cell stenting (n=43; 5-year risks, 8.6% versus 12.7%; unadjusted hazard ratio, 0.63; 95% CI, 0.37-1.05). The risk of ipsilateral stroke beyond 30 days after treatment was similar with open-cell and closed-cell stents (hazard ratio, 0.78; 95% CI, 0.35-1.75). Conclusions- Moderate or higher restenosis after CAS occurred less frequently in patients treated with open-cell stents than closed-cell stents. However, both stent designs were equally effective at preventing recurrent stroke during follow-up. Clinical Trial Registration- URL: http://www.isrctn.com/. Unique identifier: ISRCTN25337470.

Keywords: carotid artery; carotid stenosis; endarterectomy; stents; stroke.