Comparison of the uniform-field electroretinogram and the pattern electroretinogram to checkerboard and bar gratings
- PMID: 31549345
- DOI: 10.1007/s10633-019-09714-6
Comparison of the uniform-field electroretinogram and the pattern electroretinogram to checkerboard and bar gratings
Abstract
Purpose: To compare the electroretinal response associated with the uniform-field electroretinogram (UF-ERG) to that of the pattern electroretinogram (PERG) to checkerboard and bar-grating stimuli.
Methods: UF-ERG and PERG to bars and checkerboard were recorded for 18 visually normal subjects (36 eyes) of mean age 45 years (range 20-75). UF-ERG was recorded to the increment and decrement of a 200-ms duration luminance modulation. Luminance onset and offset UF-ERG responses were averaged to produce a simulation of the PERG response. The mean amplitude and implicit time for the P50 and N95 potentials of actual and simulated PERG responses were recorded for each eye in the cohort.
Results: The simulated PERG waveform resulting from arithmetic averaging of the UF-ERG to luminance increment and decrement was characterized by prominent positive and negative components resembling those of the P50 and N95 PERG potentials. Implicit timing of the P50 potential was lengthened in the actual PERG to bars and checks relative to that of the simulation (P < 0.05, P < 0.001). Amplitude of the N95 potential was greater in the PERG to bars than in the PERG to checks (P < 0.05) or the simulated PERG (P < 0.001). The amplitude and implicit timing of all waveform components were significantly correlated between the actual and simulated PERG.
Conclusions: The UF-ERG to light onset and offset can be reliably recorded in human subjects. The extent to which the simulated PERG recapitulates the actual PERG response is better with checkerboard rather than bar-grating stimuli.
Keywords: Pattern electroretinogram; Photopic negative response; Uniform-field electroretinogram.
Similar articles
-
Sensitivity and specificity of the uniform field electroretinogram in glaucoma detection in comparison to the pattern electroretinogram.Doc Ophthalmol. 2024 Apr;148(2):97-106. doi: 10.1007/s10633-023-09960-9. Epub 2024 Jan 20. Doc Ophthalmol. 2024. PMID: 38243039
-
The uniform field and pattern ERG in macaques with experimental glaucoma: removal of spiking activity.Invest Ophthalmol Vis Sci. 2000 Aug;41(9):2797-810. Invest Ophthalmol Vis Sci. 2000. PMID: 10937600
-
Assessment of the uniform field electroretinogram for mouse retinal ganglion cell functional analysis.Doc Ophthalmol. 2023 Aug;147(1):29-43. doi: 10.1007/s10633-023-09933-y. Epub 2023 Apr 28. Doc Ophthalmol. 2023. PMID: 37106219
-
Pattern electroretinography (PERG) and an integrated approach to visual pathway diagnosis.Prog Retin Eye Res. 2001 Jul;20(4):531-61. doi: 10.1016/s1350-9462(00)00030-6. Prog Retin Eye Res. 2001. PMID: 11390258 Review.
-
Update on the pattern electroretinogram in glaucoma.Optom Vis Sci. 2008 Jun;85(6):386-95. doi: 10.1097/OPX.0b013e318177ebf3. Optom Vis Sci. 2008. PMID: 18521020 Review.
Cited by
-
Responses of Postreceptoral Pathways Elicited by L- and M-Cone Isolating ON- and OFF-Electroretinograms in Glaucoma Patients.Invest Ophthalmol Vis Sci. 2021 Jul 1;62(9):14. doi: 10.1167/iovs.62.9.14. Invest Ophthalmol Vis Sci. 2021. PMID: 34241626 Free PMC article.
References
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Research Materials