Early detection of restenosis after successful percutaneous transluminal coronary angioplasty by exercise-redistribution thallium scintigraphy
- PMID: 3155896
- DOI: 10.1016/0002-9149(85)90375-3
Early detection of restenosis after successful percutaneous transluminal coronary angioplasty by exercise-redistribution thallium scintigraphy
Abstract
The value of exercise testing and thallium scintigraphy in predicting recurrence of angina pectoris and restenosis after a primary successful transluminal coronary angioplasty (PTCA) was prospectively evaluated. In 89 patients, a symptom-limited exercise electrocardiogram (ECG) and thallium scintigraphy were performed 4 weeks after they had undergone successful PTCA. Thereafter, the patients were followed for 6.4 +/- 2.5 months (mean +/- standard deviation) or until recurrence of angina. They all underwent a repeat coronary angiography at 6 months or earlier if symptoms recurred. PTCA was considered successful if the patients had no symptoms and if the stenosis was reduced to less than 50% of the luminal diameter. Restenosis was defined as an increase of the stenosis to more than 50% luminal diameter. The ability of the thallium scintigram (presence of a reversible defect) to predict recurrence of angina was 66%, vs 38% for the exercise ECG (ST-segment depression or angina at peak workload). Restenosis was predicted in 74% of patients by thallium scintigraphy, but only in 50% of patients by the exercise ECG. Thus, thallium scintigraphy was highly predictive but the exercise ECG was not (p less than 0.005). These results suggest that restenosis had occurred to some extent already at 4 weeks after the PTCA in most patients in whom it was going to occur.
Similar articles
-
Predictive value of early maximal exercise test and thallium scintigraphy after successful percutaneous transluminal coronary angioplasty.Br Heart J. 1985 Feb;53(2):194-200. doi: 10.1136/hrt.53.2.194. Br Heart J. 1985. PMID: 3155619 Free PMC article.
-
Quantitative exercise thallium-201 scintigraphy for predicting angina recurrence after percutaneous transluminal coronary angioplasty.Am J Cardiol. 1989 Mar 1;63(9):517-21. doi: 10.1016/0002-9149(89)90891-6. Am J Cardiol. 1989. PMID: 2521977
-
Noninvasive prediction of restenosis after coronary angioplasty: a head to head comparison among exercise ECG, dipyridamole and exercise thallium scintigraphy.J Invasive Cardiol. 1994 Jan-Feb;6(1):1-6. J Invasive Cardiol. 1994. PMID: 10146699
-
Role of exercise testing in relationship to coronary artery bypass surgery and percutaneous transluminal coronary angioplasty.Cardiology. 1986;73(4-5):242-58. doi: 10.1159/000174018. Cardiology. 1986. PMID: 2944582 Review.
-
Strategy of diagnostic imaging before and after PTCA.Echocardiography. 1995 May;12(3):303-9. doi: 10.1111/j.1540-8175.1995.tb00553.x. Echocardiography. 1995. PMID: 10150476 Review.
Cited by
-
Downregulation of cyclin-dependent kinase 2 activity and cyclin A promoter activity in vascular smooth muscle cells by p27(KIP1), an inhibitor of neointima formation in the rat carotid artery.J Clin Invest. 1997 May 15;99(10):2334-41. doi: 10.1172/JCI119414. J Clin Invest. 1997. PMID: 9153274 Free PMC article.
-
Indications for routine heart-catheterization after CABG and PTCA.Int J Card Imaging. 1993;9 Suppl 1:71-6. doi: 10.1007/BF01143148. Int J Card Imaging. 1993. PMID: 8409546 Review.
-
QT dispersion plus ST-segment depression: a new predictor of restenosis after successful percutaneous transluminal coronary angioplasty.Clin Cardiol. 1999 Jun;22(6):409-12. doi: 10.1002/clc.4960220608. Clin Cardiol. 1999. PMID: 10376180 Free PMC article.
-
Pathological changes induced by repeated percutaneous transluminal coronary angioplasty.Br Heart J. 1987 Dec;58(6):635-43. doi: 10.1136/hrt.58.6.635. Br Heart J. 1987. PMID: 2962621 Free PMC article.
-
Angioplasty for stable versus unstable angina pectoris: are unstable patients more likely to get restenosis? A quantitative angiographic study in 339 consecutive patients.Int J Card Imaging. 1988;3(2-3):87-97. doi: 10.1007/BF01814881. Int J Card Imaging. 1988. PMID: 2971741
MeSH terms
Substances
LinkOut - more resources
Full Text Sources