Coronary pacing during percutaneous transluminal coronary angioplasty
Abstract
To avoid venous puncture, a new concept for standby cardiac pacing during percutaneous transluminal coronary angioplasty (PTCA) and diagnostic cardiac catheterization was developed. It uses an arterial guidewire as a unipolar pacing electrode with the second electrode attached to the skin. The system was tested in 25 coronary arteries of 22 patients undergoing PTCA and in the left ventricles of 10 patients undergoing diagnostic cardiac catheterization. Coronary pacing via the guidewire used for directing the balloon catheter was possible in all patients and in 24 of the 25 coronary arteries attempted. Maximum duration of pacing was 8 min. Threshold currents ranged from 1 to 15 mA (mean 5.7). Left ventricular pacing via the same wires or standard wires used for introduction of diagnostic or guiding catheters was possible in all patients and was maintained for up to 10 min. Threshold currents ranged from 1 to 7 mA (mean 3.9). Neither method for pacing produced adverse effects during these short applications. The setup for coronary pacing also allowed recording of an intracoronary electrocardiogram during PTCA. The presented system provides backup for the rare event of sustained bradycardia during PTCA or diagnostic cardiac catheterization. If applied cautiously, it may safely and reliably replace the standby of a conventional transvenous pacing catheter.
Similar articles
-
Coronary and left ventricular pacing as standby in invasive cardiology.Cathet Cardiovasc Diagn. 1992 Apr;25(4):285-9. doi: 10.1002/ccd.1810250405. Cathet Cardiovasc Diagn. 1992. PMID: 1571989
-
A novel approach for transcoronary pacing in a porcine model.J Invasive Cardiol. 2012 Sep;24(9):451-5. J Invasive Cardiol. 2012. PMID: 22954565
-
Use of pulmonary artery pressure and pacing catheter during PTCA.Cathet Cardiovasc Diagn. 1986;12(1):64-5. doi: 10.1002/ccd.1810120116. Cathet Cardiovasc Diagn. 1986. PMID: 2937538
-
Use of balloon flotation pacing catheters for prophylactic temporary pacing during diagnostic and therapeutic catheterization procedures.Am J Cardiol. 1988 Nov 1;62(13):941-4. doi: 10.1016/0002-9149(88)90897-1. Am J Cardiol. 1988. PMID: 2972189
-
Coronary Guidewires in Temporary Cardiac Pacing and Assessment of Myocardial Viability: Current Perspectives and Future Directions.J Clin Med. 2023 Nov 8;12(22):6976. doi: 10.3390/jcm12226976. J Clin Med. 2023. PMID: 38002591 Free PMC article. Review.
Cited by
-
Temporary trans-coronary pacing by coated guidewires: a safe and reliable method during percutaneous coronary intervention.Clin Res Cardiol. 2006 Apr;95(4):206-11. doi: 10.1007/s00392-006-0361-3. Epub 2006 Feb 17. Clin Res Cardiol. 2006. PMID: 16598589
-
The stability of flow velocity and intracoronary resistance in the intracoronary electrocardiogram-triggered pressure ratio.Sci Rep. 2021 Jul 5;11(1):13824. doi: 10.1038/s41598-021-93181-0. Sci Rep. 2021. PMID: 34226618 Free PMC article.
-
Efficacy of the Direct Wire Pacing Technique During a TAVR Through a Simple Electrocautery Plate.J Soc Cardiovasc Angiogr Interv. 2024 Feb 23;3(4):101343. doi: 10.1016/j.jscai.2024.101343. eCollection 2024 Apr. J Soc Cardiovasc Angiogr Interv. 2024. PMID: 39130185 Free PMC article. No abstract available.
-
Effect of pre-treatment with transdermal glyceryl trinitrate on myocardial ischaemia during coronary angioplasty.Heart. 1996 Dec;76(6):471-6. doi: 10.1136/hrt.76.6.471. Heart. 1996. PMID: 9014793 Free PMC article. Clinical Trial.
-
Algorithm for real-time analysis of intracoronary electrocardiogram.Front Cardiovasc Med. 2022 Sep 7;9:930717. doi: 10.3389/fcvm.2022.930717. eCollection 2022. Front Cardiovasc Med. 2022. PMID: 36172580 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources