Clinical performance of chairside monolithic lithium disilicate glass-ceramic CAD-CAM crowns
- PMID: 31565848
- DOI: 10.1111/jerd.12531
Clinical performance of chairside monolithic lithium disilicate glass-ceramic CAD-CAM crowns
Abstract
Objectives: To evaluate the clinical performance and the effect of various patient and provider-related factors on the longevity of chairside monolithic posterior lithium disilicate glass-ceramic (LDGC) computer-aided design (CAD)-computer-aided manufacturing (CAM) crowns provided by predoctoral students.
Materials and methods: A sample of posterior LDGC CAD-CAM crowns was evaluated. Crown preparations were milled chairside using the CEREC Omnicam system and cemented with Rely-X Unicem or Calibra Universal resin cements. Clinical assessment of the crowns and supporting periodontal structures was performed using the modified California Dental Association (CDA) criteria. Intraoral photographs as well as radiographs were taken for further assessment by two evaluators. Kaplan-Meier survival analysis was performed.
Results: A total of 40 crowns were inserted in 32 patients and evaluated for 4 years. Three complications were observed (two-technical and one-biological). No chipping or fracture of crowns was observed. No significant association was found between age, sex, periodontal condition, tooth type, tooth vitality, cement type, and longevity. The 4-year cumulative survival and success rates were 95.0 and 92.3%, respectively.
Conclusion: Chairside LDGC CAD-CAM crowns exhibited a high survival rate after 4 years in function and were shown to be a viable and reliable treatment option for posterior teeth.
Clinical significance: The high survival rate of chairside CAD-CAM crowns observed in this study suggests the likelihood of predictable performance in the predoctoral setup.
Keywords: CAD-CAM; chairside; dental crowns; lithium disilicate; longevity; survival.
© 2019 Wiley Periodicals, Inc.
References
REFERENCES
-
- Santos GC, Santos MJ, Rizkalla AS, et al. Overview of CEREC CAD/CAM chairside system. Gen Dent. 2013;61:36-40.
-
- Zaruba M, Mehl A. Chairside systems: a current review. Int J Comput Dent. 2017;20:123-149.
-
- Fasbinder DJ, Dennison JB, Heys D, Neiva G. A clinical evaluation of chairside lithium disilicate CAD/CAM crowns: a two-year report. J Am Dent Assoc. 2010;141(Suppl 2):S10-S14.
-
- Reich S, Fischer S, Sobotta B, et al. A preliminary study on the short-term efficacy of chairside computer-aided design/computer-assisted manufacturing-generated posterior lithium disilicate crowns. Int J Prosthodont. 2010;23:214-216.
-
- Seydler B, Schmitter M. Clinical performance of two different CAD/CAM-fabricated ceramic crowns: 2-year results. J Prosthet Dent. 2015;114:212-216.